KS447 Measurement and metering transformer cabinet, Field width: 3, Rows: 0, 1100 mm x 800 mm x 215 mm, Isolated (Class II), IP31 image 5

KS447 Mess- und Wandlerschrank, Aufputz A37

Laohinnas (käibemaksuta):
2 413,49 €
Hind kehtib kuni 2024-12-24
Hind m kohta: 2 413,49 €
EAN: 4011617329497
MPN: 2CPX032949R9999
Meie ladu: Ei Hankija laovaru: Ei
Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi KS447 Measurement and metering transformer cabinet, Field width: 3, Rows: 0, 1100 mm x 800 mm x 215 mm, Isolated (Class II), IP31
Bränd ABB
Kategooriad Elektrikilbid
Harmoneeritud süsteemi kood 8537 1098 00
Paigaldusviis Pinnapealne/osaliselt süvistatav
Laius 800 mm
Mudel 1-korruseline
Kõrgus 1100 mm
Sügavus 215 mm
Koos montaažiplaadiga No
Sisseehitussügavus 215 mm
Tunnusvool 250 A
Väljade arv 3
Kõrgus 1100 mm
Laius 800 mm
Materjal Terasplaat
TSG-paneele 0
Jaotusridade arv 0
Mõõtekappide arv 0
Alumine ühendusruum 5-se kogumislatiga
Kaitseaste (IP) IP31
Pakendamise üksikasjad
Pakkimistase 1 4011617329497
Downloads
Kirjeldus
Measurement and metering transformer cabinet, series A, fully assembled cabinet, Expansion option: Lateral, for the internal use, with Door, class of protection II (double insulated), degree of protection IP31, applicable standards: EN 61439-1, EN 61439-2, Rated operational voltage 415V AC 50/60 Hz, rated current 200 A, Rated current of the assembly of switchgear and controlgear InA 222 A, Powder-coated, in RAL 9016, enclosure out of sheet steel, double door, door hinge right and left, dimensions in mm (H x W x D): 1100 x 800 x 215, Earthing system TN-S, 5-pole, net side compartment, meter space: with busbar, net side compartment, meter space: with busbar, Meter replacement plate metering transformer conversion board size 1/2 or 2 (KF421, KF414), Pre-wired from current and voltage pfad up to test terminal X1, voltage path Fuse base element D01/3-pole, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse base element NH2/400 A, current transformer range CT mounting pad with CT rail 170 x 30 x 5 mm, parting point after the current transformer Switch 250 A / 3-pole (M8), primary wiring L1-L3 120 qmm, N+PE 120 qmm, Connection N+PE (M8), Note: metering transformer conversion board KF414 required, Busbar terminals should be ordered seperately, Grid unit 7 GU, Overall height 3, panel width 3, Space units 252, covers out of Plastic, Quick sealable connection, RAL 7035, pre-assembled for installation of metering exchange plate