Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
KA4205 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC image 5
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
KA4205 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC thumbnail 5

KA4205 Mess- und Wandlerfeld H5/B2 vorverdrahtet mit Zählerkreuz

Yra sandėlyje: Ne Pardavėjo atsargos: Ne Minimalus užsakymo kiekis: 1
Kaina (be PVM):
2 397,38 €
Ši kaina galioja iki 24.12.24
EAN: 4011617356981
MPN: 2CPX035698R9999
Dėžė: 1

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas KA4205 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC
Prekės ženklas ABB
Kategorijos Elektros skydai
Suderintos sistemos kodas 8537 1098 00
Spalva Pilkas
Plotis 500 mm
Modelis Dviejų aukštų
Aukštis 1350 mm
RAL numeris 7035
Su montavimo plokšte No
Jungties vieta 300 mm
Su laidynu Yes
Modulinių tarpų skaičius plotyje 24
TSG panelių skaičius 1
Paskirstytojo eilių skaičius 0
Matuoklio dėžių skaičius 1
Apatinė jungties erdvė Su 5 polių šynos juosta
Saugos laipsnis (IP) IP2XC
Pagrindinio jungiklio nominali srovė 250 A
Dangčio modelis Uždarytas su spaudavimu

Pakavimo informacija

Pakavimo lygis 1 4011617356981

Atsisiuntimai

Aprašymas

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, Rated operational voltage 415V AC 50/60 Hz, rated current 210 A, Rated current of the assembly of switchgear and controlgear InA 210 A, in RAL 7035, dimensions in mm (H x W x D): 1350 x 500 x 160, Metering module pre-wired, Earthing system TN-S, 5-pole, net side compartment, meter space: with busbar, Number of SG spaces 1, Number of transformer meter spaces 1, net side compartment, meter space: with busbar, Pre-wired according requirements DSO, voltage path Fuse base element D01/3-pole and D01/1-pole, Secondary wiring current Wiring set H07V-U, busbar system Cu busbars 2 x 12 x 5 mm 5-pole, parting point before the current transformer Fuse base element NH2/400 A, current transformer range CT mounting pad out of support insulators for CT rail with 130 mm hole distance, parting point after the current transformer Switch disconnector 250 A / 4-pole, primary wiring L1-L3, N 120 qmm, PE 95 qmm, Connection N+PE (M12), Grid unit 9 GU, Overall height 5, panel width 2, Space units 216, covers out of Plastic, Quick sealable connection, RAL 7035