Technical Information
Prekės būklė |
Nauja |
Gamintojo pavadinimas |
RS485 bus wireless three-phase energy meter, MID approval |
Prekės ženklas |
ELTAKO
|
Kategorijos |
Elektros skaitikliai
|
Kilmės šalis |
CN |
Suderintos sistemos kodas |
9028 3019 00
|
Montavimo metodas |
DRA |
Plotis |
70 mm |
Aukštis |
82 mm |
Gylis |
58 mm |
Dažnio diapazonas |
50 Hz |
Maks. srovė (Imax) |
80 A |
Modulinių tarpų skaičius plotyje |
4 |
Saugos laipsnis (IP) |
IP20 |
Poliškumas |
Keturgyslis laidas |
Nominali įtampa (Un) N-L |
230 V |
Nominali srovė (In) |
10 A |
Pakavimo informacija
Pakavimo lygis 1 |
4010312501733, 4010312501733 |
Pakavimo lygis 2 |
4010312501733 |
Kiti techniniai duomenys
Modelis |
Tiesioginis matavimas |
Tinka |
Pirkti |
Rodmens tipas |
Skaitmeninis |
Bendras skaičius (skaitiklis) |
7 |
Matuoklio tipas |
Elektroninis |
Sąsajos tipas |
RS-485 |
Kilovatvalandžių skaitiklio energijos tipo versija |
Efektinė galia |
Kilovatvalandžių skaitiklio tarifinis modelis |
Du tarifai |
Tarifo kontrolė |
Išorinis |
Išleidimo mechanizmas |
Yes |
Kalibruotas |
Yes |
Patvirtinimas |
Matavimo priemonių direktyva |
Impulsinė išvestis |
Elektrinis |
Tikslumo klasė |
B |
Apkrovos profilio matavimas |
- |
EEC40 parašas |
- |
Su blokavimo kodu |
- |
Nominali įtampa (Un) L-L |
400 V |
Atsisiuntimai
Aprašymas
RS485 bus wireless three-phase energy meter. Maximum current 3x80A. Standby loss 0.8W at L1 and only 0.5W at L2 and L3 each. Modulair device for DIN-EN 60715 TH35 rail mounting in distribution cabinets with IP51 protection class. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With RS485 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.8W or 0.5W active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The terminals ‹L1 and N must always be connected. Connection to the Eltako RS485 bus via a FBA14 by means of a 2-wire screened bus line (e.g. telephone line). The meter reading and the momentary capacity are transferred to the bus – e.g. for transfer to an external computer or a Professional Smart Home controller – and is also transferred to the wireless network via the FAM14. For this it is necessary that a device address is assigned from the wireless antenna module FAM14, according to the operating instructions. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. The power consumption is displayed with a LED flashing 1000 times per kWh next to the display. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230 V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display.