Registruokitės, kad atrakintumėte savo išskirtines B2B kainas ir pradėtumėte apsipirkinėti. Užsiregistruokite dabar!
Earth-fault release, 30mA, 3p, right image 1
Earth-fault release, 30mA, 3p, right image 2
Earth-fault release, 30mA, 3p, right image 3
Earth-fault release, 30mA, 3p, right image 4
Earth-fault release, 30mA, 3p, right thumbnail 1
Earth-fault release, 30mA, 3p, right thumbnail 2
Earth-fault release, 30mA, 3p, right thumbnail 3
Earth-fault release, 30mA, 3p, right thumbnail 4

Earth-fault release, 30mA, 3p, right

Yra sandėlyje: Ne Pardavėjo atsargos: Ne Minimalus užsakymo kiekis: 1
Kaina (be PVM):
286,91 €
Ši kaina galioja iki 24.12.24
EAN: 4015081044139
MPN: 104603
Pakuotė: 1

Technical Information

Prekės būklė Nauja
Gamintojo pavadinimas Earth-fault release, 30mA, 3p, right
Prekės ženklas EATON
Kategorijos Priedai (automatika ir valdymas)
Kilmės šalis CZ
Suderintos sistemos kodas 8538 9099 00
Reguliuojama delsa No
Nominali gedimo srovė nuo / iki 0.03 A
Nominali kontrolės maitinimo įtampa, kai AC 50 Hz 200-415 V
Nominali kontrolės maitinimo įtampa, kai AC 60 Hz 200-415 V
DC nominali kontrolės maitinimo įtampa 0 V
Maks. nominali operacinė įtampa Ue 415 V
Maks. aktyvavimo delsos laikas 30 ms

Pakavimo informacija

Pakavimo lygis 1 4015081044139

Aprašymas

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: approved according to IEC/EN 60947-2 not UL/CSA approved. Suitable for use in three- and single-phase systems. Pulse current sensitive according to core-balance principle. For 3 and 4 pole NZM1(-4) circuit-breakers and switch-disconnectors N1(-4).mains voltage independent Ue = 200 .. 415 V 50/60 Hz. At I △n = 0.03 A: delay time t v always fixed setting to 10 ms. Warning message > 30 % I △n by yellow LED . Trip indication max. 2 auxiliary contacts (HIAFI) can be fitted by user: N/O = M22-K01, N/C = M22-K10 are reset via the reset button. If the trip-indicating auxiliary contact in the fault current block is used, the N/C contacts operates as a N/O contact and the N/C contact operates as an N/O contact. Double contact not permissible. Not in combination with insulated enclosure or main switch assembly kit for side panel mounting with mounting bracket. NZM1-XFI...R can not be used in combination with lower cover NZM1-XUSA.NZM1-XFI…U not in combination with shunt or undervoltage release, early-make auxiliary contacts . Rated ultimate short-circuit breaking capacity is determined by fitted NZM1, NS1. When using a switch-disconnector N1, by the back-up fuse to be used. See technical data. Can be used for: NZM1, N(S)1