RS485 bus actuator multifunction impulse switch with iIntegrated relay function image 1

RS485 bus actuator multifunction impulse switch with iIntegrated relay function

Sandėlyje esančios prekės kaina (be PVM):
47,09 €
Ši kaina galioja iki 2024-12-31
Kaina už m: 47,09 €
EAN: 4010312313725
MPN: 30014003
Mūsų sandėlis: Ne Pardavėjo atsargos: Ne
Už pakuotę: 1 Už dėžę: 1 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas RS485 bus actuator multifunction impulse switch with iIntegrated relay function
Prekės ženklas ELTAKO
Kategorijos Jutikliai
Kilmės šalis CN
Suderintos sistemos kodas 8526 9200 00
Montavimo metodas DRA
Nustatyta srovė 16 A
Išeigos galia 2000 W
Nominali operacinė įtampa 12 V
EIB / KNX magistralės sistema No
Magistralės sistemos radijo dažnis Yes
„Powernet“ magistralės sistema No
Maks. perjungimo galia 2000 W
Įtraukta magistralės jungtis Yes
Maks. perjungiamų kontaktų skaičius 1
Modulinių tarpų skaičius plotyje 1
Maks. perjungimo srovė 16 A
Kitos maršrutinės sistemos Nėra
LON magistralinė sistema No
C apkrova -
Prijungiamas prie skirtingų fazių No
Lokali operacija / rankos operacija No
Saugos laipsnis (IP) IP20
Su LED rodmeniu No
Modulinis praplečiamumas No
KNX radijo magistralės sistema No
Dvikryptis radijas Yes
Nuimamas magistralės (šynos) modulis Yes
Maks. perjungimo maitinimo šviesos diodas 400 W
Pakavimo informacija
Pakavimo lygis 1 4010312313725, 4010312313725
Pakavimo lygis 2 4010312313725
Pakavimo lygis 3 4010312313725
Downloads
Aprašymas
Multifunction impulse switch with integrated relay function, 1+1 NO ­potential free 16A/250V AC, 230V LED lamps up to 400W, incandescent lamps 2000W, with DX ­technology. Bidirectional. Only 0.1-0.6 watt standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. Patented Eltako Duplex technology allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to K(L). This results in an additional standby consumption of only 0.1 watt. Maximum current over both contacts 16A for 230V. If supply voltage fails, the device is switched off in defined mode. When both relays of the FMS14 are switched on, 0.6 watt are required. The upper and the middle rotary switches are for teaching-in the sensors. In normal mode, the middle rotary switch is then set to AUTO and the bottom rotary switch to the required function: 2S = Impulse switch with 2 NO contacts. (2xS) = 2-way impulse switch each with one NO relay. WS = Impulse switch with 1 NO contact and 1 NC contact (0.3 watt standby loss). SS1 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 1. SS2 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 2. SS3 = Impulse multi circuit switch 1+1 NO contacts for switching sequence 3. GS = Impulse group switch 1+1 NO ­contacts. 2R = Switching relay with 2 NO contacts. WR = Switching relay with 1 NO contact and 1 NC contact (0.3 watt standby loss). RR = Switching relay (closed-circuit current relay) with 2 NC contacts (0.5 watt standby loss). GR = Group relay 1+1 NO contacts. Switching sequence SS1: 0 - contact 1 (K-1) - contact 2 (K-2) - contact 1 + 2. Switching sequence SS2: 0 - contact 1 - contact 1 + 2 - contact 2. Switching sequence SS3: