Techniniai duomenys
Prekės būklė Nauja
Prekės ženklas Schneider Electric
Kategorijos Apsauga nuo nuotėkio
Kilmės šalis PT
Montavimo metodas DIN bėgis
Įtampos tipas Kintamoji srovė
Suprojektuotas gylis 44.000 mm
Nustatyta srovė 25.000 A
Nustatyta įtampa 400.000 V
Nominali izoliacinė įtampa Ui 500.000 V
Polių skaičius 4.000
Nominali gedimo srovė 300.000 A
Srovės nutekėjimo tipas A
Selektyvinė apsauga No
Trumpo jungimosi sistemos išjungimo pajėgumas (lcw) 10.000 kA
Srovės padidėjimo intensyvumas 0.250 kA
Užterštumo laipsnis 2.000
Modulinių tarpų skaičius plotyje 7.000
Trumpalaikis ribinis delsos atjungimas No
Apsaugotas nuo sprogimo No
Dažnis 50 Hz
Saugos laipsnis (IP) IP20
Prijungiamo laidininko kryžminės sekcijos vientisa šerdis 1.500-2.500 mm²
Prijungiamo laidininko kryžminės sekcijos įvairialypis laidynas 1.500-2.500 mm²
Su užblokavimo įrenginiu Yes
Aplinkos temperatūra operaciniu metu -5.000-40.000 °C
Galima papildoma įranga Yes
Nurodytoji atlaikoma impulsinė įtampa 4.000 kV
Pakavimo informacija
Pakavimo lygis 1 3303430182658
Pakavimo lygis 2 3303430182656
Downloads
Aprašymas
This Acti9 REDs is a modular residual current circuit breaker (RCCB) with recloser. It is a 4P circuit breaker with In rated current of 25A, A type protection class and a 300mA earth leakage sensitivity. This product protects against electrical shock by indirect contact and fire hazards. It disconnects of on-load electric circuits already protected against overloads and short-circuits. It restarts automatically after insulation monitoring of the downstream circuit. It is only used on TT and TN-S earthing grounding systems. The Acti9 REDs and REDtest versions are dedicated to tertiary,industrial and infrastructure applications. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 630A. The (Inc/IΔc) conditional rated short circuit current is 6kA. It has a mechanical endurance going up to 4000 cycles. The maximum duration of a restart cycle is below 10s. The Ue operational voltage is 400VAC. The test button minimum operating voltage is 170VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz. It is DIN rail mountable. The width in 9mm pitches is 14. The dimensions are (W) 125mm x (H) 98mm x (D) 79.5mm. The weight is 0.67kg. It has an IP20 degree of protection. It becomes IP40 once in modular enclosure according to IEC/EN 60529 standard. The operating temperature is from -5°C to 40°C. The storage temperature is from -20°C to 60°C.