Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
MD01 image 1
MD01 image 2
MD01 image 3
MD01 image 4
MD01 image 5
MD01 image 6
KA4272 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC image 7
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
MD01 thumbnail 5
MD01 thumbnail 6
KA4272 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC thumbnail 7

KA4272 Mess- und Wandlerfeld BH5 vorverdrahtet mit Zählerkreuz

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
2 783,27 €
Hind kehtib kuni 31.12.24
EAN: 4011617338284
MPN: 2CPX033828R9999
Karp: 1

Technical Information

Toote seisukord Uus
Tootja nimi KA4272 Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC
Bränd ABB
Kategooriad Elektrikilbid
Harmoneeritud süsteemi kood 8537 1098 00
Värvus Hall
Laius 500 mm
Mudel 2-korruseline
Kõrgus 1350 mm
RAL-number 7035
Koos montaažiplaadiga No
Ühendusvahe 300 mm
Koos juhtmestusega Yes
Laius mooduli arvudes 24
TSG-paneele 1
Jaotusridade arv 0
Mõõtekappide arv 1
Alumine ühendusruum 5-se kogumislatiga
Kaitseaste (IP) IP2XC
Peaahela lüliti tunnusvool 250 A
Katte kuju Suletud eelstantsimisega

Pakendamise üksikasjad

Pakkimistase 1 4011617338284

Allalaadimised

Kirjeldus

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, EN 61439-3, Rated operational voltage 415V AC 50/60 Hz, rated current 220 A, Rated current of the assembly of switchgear and controlgear InA 222 A, in RAL 7035, dimensions in mm (H x W x D): 1350 x 500 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path Fuse base element D01/3-pole, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse base element NH2/400 A, current transformer range CT mounting pad with CT rail 30 x 5 mm, parting point after the current transformer Switch 250 A / 3-pole (M8), primary wiring Cu-Busbar 30 x 5 mm, Accessible to Cu busbar, outgoing: terminals screws to fuse disconnetor and PE+N busbar, Connection N+PE (M8), Note: In case short circuit is > 25 kA, Backup protection required for voltage path circuit. Short circuit value to be obtained from DSO. Busbar terminals should be ordered seperately, Grid unit 9 GU, Overall height 5, panel width 2, Space units 216, covers out of Plastic, Quick sealable connection, RAL 7035