Register to unlock your exclusive B2B prices. Register now
MD01 image 1
Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A image 2
Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A image 3
Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A image 4

Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A

Laohinnas (käibemaksuta):
33,47 €
Hind kehtib kuni 2024-12-24
Hind m kohta: 33,47 €
EAN: 3606480482809
MPN: A9Z04440
Meie ladu: Ei Hankija laovaru: Jah
Pakendi kohta: 1 Kasti kohta: 27 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Acti9 ID K - residual current circuit breaker - 4P - 40A - 300mA - type A
Bränd Schneider Electric
Kategooriad Lekkekaitse
Paigaldusviis DIN liist
Pinge liik AC
Sisseehitussügavus 44 mm
Tunnusvool 40 A
Tunnuspinge 400 V
Isolatsiooni nimipinge Ui 440 V
Pooluste arv 4
Tunnus-rikkevool 300 A
Rikkevoolu liik A
Selektiivne kaitse No
Lühisvoolu lahutusvõime (Icw) 10 kA
Löökvoolutaluvus 0.25 kA
Saasteaste 2
Laius mooduli arvudes 4
Lühiajalise viibega rakendumine No
Plahvatuskindel No
Sagedus 50/60 Hz
Kaitseaste (IP) IP20
Ühendatava juhi ristlõige, massiivsoonega 1-35 mm²
Ühendatava juhi ristlõige, mitmekiuline 1-25 mm²
Blokeerimisseadmega No
Talitlusaegne ümbrustemperatuur -25-40 °C
Lisaseadmed on võimalikud Yes
Tunnus-impulsstaluvuspinge Uimp 4 kV
Pakendamise üksikasjad
Pakkimistase 1 3606480482809
Pakkimistase 2 3606480482807
Downloads
Kirjeldus
This Acti9 ID K product is a biconnect residual current circuit breaker (RCCB). It is a 4P circuit breaker with 40A In rated current, 300mA earth leakage sensitivity and A type protection class. This product protects against electrical shock by indirect contact and fire hazards. There is a test button used to check the residual current device is operating correctly. The connection is made downstream by biconnect comb busbar or upstream/downstream by tunnel terminals. This product is compliant with IEC/EN 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 500A. The (Inc/IΔc) conditional rated short circuit current is 4.5kA. It has an electrical endurance going up to 2000 cycles and a mechanical endurance going up to 5000 cycles. The Ue operational voltage is 380VAC to 415VAC. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 8. The product colour is white (RAL9003). The dimensions are (W) 72mm x (H) 81mm x (D) 68mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -25°C to 40°C. The storage temperature is from -30°C to 70°C.