Advanced control unit, TeSys Ultra, 4.5-18A, 3P motors, protection & diagnostic, class 10, coil 48-72V AC/DC

Laohinnas (käibemaksuta):
77,01 €
Hind kehtib kuni 2024-12-24
Hind m kohta: 77,01 €
EAN: 3389110364224
MPN: LUCB18ES
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 23 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Advanced control unit, TeSys Ultra, 4.5-18A, 3P motors, protection & diagnostic, class 10, coil 48-72V AC/DC
Bränd Schneider Electric
Kategooriad Tarvikud (automaatika ja juhtimine)
Päritoluriik FR
Harmoneeritud süsteemi kood 8537 1098 99
Nominaalne püsivool Iu 18 A
Pooluste arv 3
Lühisvabasti funktsioon Viivituseta
Liigkoormuskaitse sättepiirkond 4.5-18 A
Juhtahelate tunnus-toitepinge, AC 50 Hz 48 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 48 V
Juhtahelate tunnus-toitepinge, DC 48-72 V
Maaühenduse rikkekaitsefunktsiooniga Yes
Viivituseta lühisvabasti sättepiirkonna algväärtus 234 A
Viivituseta lühisvabasti sättepiirkonna lõppväärtus 234 A
Mootorikaitse liik Electronic release
Aktiveerimispinge liik AC/DC
Pakendamise üksikasjad
Pakkimistase 1 3389110364224
Pakkimistase 2 3389110364222
Downloads
Kirjeldus
TeSys U control and diagnostic unit to be inserted in advanced power bases LUB320, LUB380, LUB380 to form a TeSys U starter controller, for 3-phase motor applications up to 7.5kW@400V. It provides full protection to motors with a rated current Ir 4.5-18A (Ir adjustable), overload tripping class 10, short circuit at 13 x Irmax, overcurrent at 14.2 x Ir, phase loss, insulation fault (protection of equipment only). For diagnostics, it provides a thermal overload alarm to be managed with an additional function module (to be ordered separately) and a test push button for overload simulation. To be used with a 48V AC / 48-72V DC voltage for the control of the starter (through the control terminals A1/A2 located in the power base). Certified when used in conjunction with a LUB power base (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).