Register to unlock your exclusive B2B prices. Register now
Blind actuator REG-K/2x/10 with manual mode, light grey image 1
Blind actuator REG-K/2x/10 with manual mode, light grey image 2
Blind actuator REG-K/2x/10 with manual mode, light grey image 3
Blind actuator REG-K/2x/10 with manual mode, light grey image 4

Blind actuator REG-K/2x/10 with manual mode, light grey

Laohinnas (käibemaksuta):
166,49 €
Hind kehtib kuni 2024-12-24
Hind m kohta: 166,49 €
EAN: 3606485011844
MPN: MTN649802
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 10 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Blind actuator REG-K/2x/10 with manual mode, light grey
Bränd Schneider Electric
Kategooriad Andurid
Päritoluriik DE
Harmoneeritud süsteemi kood 8537 1098 99
Paigaldusviis DRA (DIN liistule)
Voolu liik AC
Sisendite arv 0
Siinisüsteem KNX Yes
Raadiosageduslik siinisüsteem No
Siinisüsteem Powernet No
Suurim lülitusvõimsus 1000 W
Siiniühendusega Yes
Ribikardina väljundite suurim arv 2
Lülitusvool (aktiivkoormus) 10 A
Laius mooduli arvudes 4
Muud siinisüsteemid Puudub
Siinisüsteem LON No
Lokaaljuhtimine/käsijuhtimine Yes
Lülitusfunktsiooniga No
Kaitseaste (IP) IP20
LED näidikuga Yes
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline No
Eemaldatav siini moodul No
Sisseehitatud paigalduskarbi vähim sügavus 0 mm
Pakendamise üksikasjad
Pakkimistase 1 3606485011844
Pakkimistase 2 3606485011842
Downloads
Kirjeldus
KNX blind actuator REG-K/2x/10 with manual mode. For independent control of 2 blind/roller shutter drives. The function of the blind channels is freely configurable. All blind outputs can be operated manually using push-button operation. Channel status display via LEDs. A green LED indicates readiness for operation. With integrated bus coupler. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. A data rail is not necessary. KNX software functions: Blind functions: Blind type. Running time. Idle time. Step interval. Differentiated disable functions and weather alarms. 8-bit positioning for height and slat. Scenes. Manual/automatic mode. Differentiated status and status feedback functions. For each blind output: Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. Nominal current: 10 A, inductive load cos Phi 0.6. Motor load: AC 100 V, max. 434 W. AC 230 V, max. 1000 W. AC 240 V, max. 1043 W. Device width: 4 modules, approx. 72 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.