Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
MD01 image 1
circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d image 2
circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d image 3
circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d image 4
MD01 thumbnail 1
circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d thumbnail 2
circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d thumbnail 3
circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d thumbnail 4

circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
447,12 €
Hind kehtib kuni 24.12.24
EAN: 3606480259326
MPN: LV563550
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 500 A rating magnetic MA trip unit, 3P 3d
Bränd Schneider Electric
Kategooriad Mootori kaitselülitid
Laius 140 mm
Kõrgus 255 mm
Sügavus 110 mm
Tunnustalitlusvõimsus, AC-3, 400 V 0 kW
Sisseehitatud abilülitiga Yes
Nominaalne püsivool Iu 630 A
Sisseehitatud alapingevabastiga Yes
Pooluste arv 3
Tunnus-talitluspinge 220-440 V
Kaitseaste (IP) IP40
Termokaitsega No
Peaahela ühendusviis Kruviühendus
Juhtelemendi liik Muul viisil
Väljalülituspõhimõte Magnetiline
Nominaalne käitusvõimsus AC-3, 230 V korral 0 kW
Nimi lahutusvõime lühisel Icu 400 V AC korral 36 kA
Viivituseta lühisvabasti seadistuspiirkond 3000-6500 A
Faasirikketundlik No
Seadme ehitus Fikseeritud paigaldusega seade

Pakendamise üksikasjad

Pakkimistase 1 3606480259326

Allalaadimised

Kirjeldus

This device is a rated current 500A circuit breaker from EasyPact CVS630F. The rated breaking capacity(Ics) is 36kA at 415VAC,and complete range with Ics=100%Icu. The version of breaker is 3poles frame with detection on 3poles, also accompanied MA trip unit for magnetic protection. It is conformed to standard IEC60947-2 for circuit breakers part. This device is certified for operation in pollution degree III environment as defined IEC60947-1& IEC60664-1, and respected for RoHs requirement as european environment directive EC/2002/95. It can be mounted by blackplate or Din rail,also through the door of class II switchboard without downgrading switchboard insulation. The front of toggle offers IP40 protection, but when it is equiped extended rotary handle inside the switchboard, additional IP54 protection degree for extended rotary handle. This series have slots for electrical auxiliaries(MN/MX/OF/SD),depending on the type of trip unit if rotary handle installed. The fixed dimension is 140mm width.255mm height,110mm depth,