EATON

Contact element, Cage Clamp, Front fixing, 2 N/O, 24 V 3 A, 220 V 230 V 240 V 4 A, big pack

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
9,49 €
Hind kehtib kuni 24.12.24
EAN: 4015081997527
MPN: 199880
Pakend: 1
Karp: 100

Technical Information

Toote seisukord Uus
Tootja nimi M22-CK20-GVP Eaton Moeller® series M22 Accessory Contact element
Bränd EATON
Kategooriad Tarvikud (automaatika ja juhtimine)
Päritoluriik DE
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis Eesmine kinnitus
Mudel Ülapaigaldusega ja integreeritav
Lambipesa Puudub
Tunnus-talitlusvool Ie, AC-15, 230 V 6 A
Elektriühenduse liik Vedruklamber ühendus
Rikkesignaali lülitite arv 0
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 2
Ümberlülituskontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 4015081997527
Pakkimistase 2 4015081997176

Kirjeldus

Contact element, Standard/Approval: UL/CSA, IEC, Construction size: NZM1/2/3/4, Connection technique: Cage Clamp, Fixing: Front fixing, Description: When using emergency switching off actuators M22-PV… max. 2 contact elements = 4 NC / N/O contacts, Cage Clamp is a registered trademark of Wago Kontakttechnik GmbH/Minden, Germany, Contacts N/O = Normally open: 2 N/O, Degree of Protection: IP20, Connection to SmartWire-DT: no, Connection type: Double contact, Description of HIA trip-indicating auxiliary contact: General trip indication '+', when tripped by shunt release, overload release , short-circuit release or by the residual-current release due to residual-current., Can be used with NZM1, 2, 3 circuit-breaker: a trip-indicating auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM4 circuit-breaker: up to two standard auxiliary contacts can be clipped into the circuit-breaker., Any combinations of the auxiliary contact types are possible., Not in combination with switch-disconnector PN…, Marking on switch: HIA, Labeling in FI-Block: HIAFI., If the trip-indicating auxiliary switch in the fault current block is used , the NC contacts operates as a N/O contact and the N/O contact operates as an NC contact., Description standard auxiliary contact HIN: Switching with the main contacts Used for indicating and interlocking tasks., Can be used with NZM1 circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM2 size circuit-breaker: a standard auxiliary contact can be clipped into the circuit-breaker., Can be used with NZM3, 4 circuit-breaker: up to three standard auxiliary contacts can be clipped into the circuit-breaker.