Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Contactor, 3 pole, 380 V 400 V 22 kW, RDC 24: 24 - 27 V DC, DC operation, Spring-loaded terminals |
Bränd |
EATON
|
Kategooriad |
Modulaarsed lülitid
|
Päritoluriik |
RO |
Harmoneeritud süsteemi kood |
8536 4900 00
|
Sobib DIN paigalduspaneelidele |
No |
Tunnustalitlusvõimsus, AC-3, 400 V |
22 kW |
Normaalselt avatud peakontaktide arv |
3 |
Normaalselt suletud peakontaktide arv |
0 |
Normaalselt avatud abikontaktide arv |
0 |
Normaalselt suletud abikontaktide arv |
0 |
Tunnus-talitlusvool Ie, AC-3, 400 V |
50 A |
Tunnus-talitlusvool Ie, AC-1, 400 V |
80 A |
Juhtahelate tunnus-toitepinge, AC 50 Hz |
0 V |
Juhtahelate tunnus-toitepinge, AC 60 Hz |
0 V |
Juhtahelate tunnus-toitepinge, DC |
24-27 V |
Peaahela ühendusviis |
Vedruklamber ühendus |
Aktiveerimispinge liik |
DC |
Nimitöövool AC-4, 400 V korral |
21 A |
Tunnustalitlusvõimsus Ie, AC-4, 400 V |
10 kW |
Tunnustalitlusvõimsus (NEMA) |
29.8 kW |
Pakendamise üksikasjad
Pakkimistase 1 |
4015082780098 |
Kirjeldus
Contactor, Application: Contactors for Motors, Contactors up to 170 A, 3 pole, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Spring-loaded terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Spring-cage terminals on auxiliary and control circuit terminals, Number of poles: 3 pole, Rated operational current AC-3 380 V 400 V: Ie= 50 A , Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 80 A, enclosed: Ith= 58 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 162 A, enclosed: Ith= 145 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 15.5 kW, 380 V 400 V: P= 22 kW, 660 V 690 V: P= 30 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 6 kW, 380 V 400 V: P= 10 kW, 660 V 690 V: P= 14 kW, Can be combined with auxiliary contact: DILM150-XHIC(V).., DILM1000-XHIC.., Instructions: Contacts to EN 50 012., Auxiliary current , coil connections with spring-cage connection technology., Main current connections with screw terminals., integrated suppressor circuit in actuating electronics, Voltage AC/DC: DC operation