Register to unlock your exclusive B2B prices. Register now
Control unit 0-10 V REG-K/3-gang with manual mode, light grey image 1
Control unit 0-10 V REG-K/3-gang with manual mode, light grey image 2
Control unit 0-10 V REG-K/3-gang with manual mode, light grey image 3
Control unit 0-10 V REG-K/3-gang with manual mode, light grey image 4

Control unit 0-10 V REG-K/3-gang with manual mode, light grey

Laohinnas (käibemaksuta):
182,48 €
Hind kehtib kuni 2024-09-30
Hind m kohta: 182,48 €
EAN: 3606485100036
MPN: MTN646991
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 10 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Control unit 0-10 V REG-K/3-gang with manual mode, light grey
Bränd Schneider Electric
Kategooriad Andurid
Päritoluriik DE
Paigaldusviis DRA (DIN liistule)
Väljundite arv 3
Suurim lülitusvool (aktiivkoormus) 16 A
Siinisüsteem KNX Yes
Raadiosageduslik siinisüsteem No
Siinisüsteem Powernet No
Suurim lülitusvõimsus 3600 W
Siiniühendusega Yes
Suurim juhtimisvool 100 mA
Laius mooduli arvudes 4
Muud siinisüsteemid Puudub
Valgusanduriga sisendite arv 0
Siinisüsteem LON No
Alajaama sisend No
Lokaaljuhtimine/käsijuhtimine Yes
Kaitseaste (IP) IP20
LED näidikuga No
Liides 1-10 V Yes
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline No
Sisseehitatud paigalduskarbi vähim sügavus 0 mm
Pakendamise üksikasjad
Pakkimistase 1 3606485100036
Pakkimistase 2 3606485100034
Downloads
Kirjeldus
Control unit 0-10 V REG-K/3-gang with manual mode. For connecting devices with 0-10 V interface to KNX. With integrated bus coupler and screw terminals (230 V) or plug-in screw terminals (0-10 V). Each individual 230 V switch output can be operated manually with a manual switch. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. KNX software functions: Different dimming curves and dimming speeds, the same dimming time, memory function, ON/OFF delay, staircase time function with/without manual OFF function. Scenes (up to eight stored brightness values can be retrieved), central function, logic operation or priority control, blocking function, status feedback, behaviour on bus voltage recovery. Switch contact: for switching the electronic ballasts/transformers. Nominal voltage: AC 230 V, 50-60 Hz. Nominal current: 16 A, cos Phi 0.6. Switching capacity: AC 230 V, 3600 W, cos Phi 1. Capacitive load: AC 230 V, 16 A, 200 µF. Incandescent lamps: AC 230 V, max. 3600 W. Halogen lamps: AC 230 V, max. 2500 W. Fluorescent lamps: AC 230 V, max. 3600 VA, uncompensated. AC 230 V, max. 2500 VA, with parallel compensation. LV- halogen lamps with wound transformer: max. 2000 VA. 0-10 V interface: 0.12-100 mA. Voltage range: DC 0-10 V. Device width: 4 modules, ca. 72 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.