Three-phase energy meter, without approval image 1

Three-phase energy meter, without approval

Laohinnas (käibemaksuta):
95,00 €
Hind kehtib kuni 2024-12-31
Hind m kohta: 95,00 €
EAN: 4010312501719
MPN: 28380615
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 1 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Three-phase energy meter, without approval
Bränd ELTAKO
Kategooriad Elektrimõõdikud
Päritoluriik CN
Harmoneeritud süsteemi kood 9028 3019 00
Paigaldusviis DRA (DIN liistule)
Laius 70 mm
Kõrgus 82 mm
Sügavus 58 mm
Sagedus 50 Hz
Suurim vool (Imax) 80 A
Laius mooduli arvudes 4
Kaitseaste (IP) IP20
Impulsside sagedus 1000 Imp/kWh (kvarh)
Poolused Neljajuhiline
Tunnuspinge (Un) N-L 230 V
Tunnusvool (In) 10 A
Pakendamise üksikasjad
Pakkimistase 1 4010312501719, 4010312501719
Pakkimistase 2 4010312501719
Downloads
Muud tehnilised andmed
Mudel Vahetu mõõtmine
Sobib .. Ost/tarne
Näidiku liik Digitaalne
Arvesti (loenduri) kohtade arv 7
Arvesti liik Elektrooniline
Liidese tüüp Muul viisil
Energia liik Aktiivvõimsus
Tariifi liik Kahetariifne
Escapement mehhanism Yes
Kalibreeritud No
Impulssväljund Optiline
Impulsi liik S0
Täpsusklass B
Koormusdiagrammi mõõtmine -
EEC40 signature -
Blokeeringukoodiga -
Tunnuspinge (Un) L-L 400 V
Kirjeldus
Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. Like all meters without ­declaration of conformity (e.g. MID), this meter is not permitted for billing. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong 'false' and the corresponding phase conductor are indicated on the display.