Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
E298-16-11 Main contact module 16A, 1NO+1NC image 1
E298-16-11 Main contact module 16A, 1NO+1NC image 2
E298-16-11 Main contact module 16A, 1NO+1NC thumbnail 1
E298-16-11 Main contact module 16A, 1NO+1NC thumbnail 2

E298-16-20 Main contact module 16A, 2NO

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
13,00 € tk kohta
Hind kehtib kuni 31.12.24
EAN: 7612270939954
MPN: 2CCA704321R0001
Pakend: 10

Technical Information

Toote seisukord Uus
Tootja nimi E298-16-11 Main contact module 16A, 1NO+1NC
Bränd ABB
Kategooriad Releed
Paigaldusviis DIN liist
Funktsioon Mehaaniline
Sisseehitussügavus 62 mm
Tunnusvool 16 A
Laius mooduli arvudes 0.5
Toitepinge liik AC
Toitepinge 250 V
Suurim lülitusvool (cos phi = 0.6) 0 A
Suurim hõõglampide koormus 0 W
Suurim luminofoorlampide koormus 0 VA
Suurim luminofoorlampide koormus (kaks ahelat) 0 VA
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) 0 VA
Normaalselt suletud kontaktide arv 1
Normaalselt avatud kontaktide arv 1
Ümberlülituskontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 7612270939954, 7612270939954

Allalaadimised

Kirjeldus

Installation relays are electromagnetically operated miniature contactors in the standard DIN width of 18 mm. A reliable control system can be designed using these ABB Installation relays E297. They are used mainly in industrial plants but also in commercial and public buildings. As a rule, installation relays operated by means of a control switch (maintained contact) are installed where it is necessary to operate lighting, an air-conditioning system, a fan or suchlike. Installation relays are also referred to as monostable switching relays or 2-pole miniature contactors. The term "monostable" means that an on command has to be sent to the coil by means of a control switch (maintained operation) in order to excite the magnetic coil. The coil armature attracts and closes or opens the main contacts. The device remains in the on position for as long as the control voltage is applied to the coil. If the voltage flow to the coil is interrupted, the installation relay always returns to the neutral position (off position). Installation relays and the accessories are available in different versions in order to easily satisfy the various market requirements. Their optimal switching capacity also makes them suitable for use in industrial environments and in situations where it is necessary to ensure control over more powerful consumers (such as e.g. multiple lighting ystems). Using an optimized coil (low power loss = lower operating temperature) ensures a clean and safe operation in the electrical distribution board.