Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC image 1
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC image 2
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC image 3
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC image 4
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC thumbnail 1
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC thumbnail 2
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC thumbnail 3
electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC thumbnail 4

electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
52,50 €
Hind kehtib kuni 24.12.24
EAN: 3389110575866
MPN: LR97D25B
Pakend: 1
Karp: 24
Kaubaalus: 384

Technical Information

Toote seisukord Uus
Tootja nimi electronic overload relay for motor TeSys - 5...25 A - 24 V AC/DC
Bränd Schneider Electric
Kategooriad Juhtseadmed
Päritoluriik KR
Harmoneeritud süsteemi kood 8536 4190 89
Paigaldusviis Vahetu kinnitamine
Normaalselt avatud abikontaktide arv 0
Normaalselt suletud abikontaktide arv 0
Ümberlülituvate abikontaktide arv 1
Juhtahelate tunnus-toitepinge, AC 50 Hz 24 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 24 V
Juhtahelate tunnus-toitepinge, DC 24 V
Vabasti klass Reguleeritav
Peaahela ühendusviis Kruviühendus
Voolu seadistuspiirkond 5-25 A
Aktiveerimispinge liik AC/DC
Ennistusfunktsiooni sisend Yes
Automaatne ennistusfunktsioon Yes
Nupplülitiga ennistusfunktsioon Yes

Pakendamise üksikasjad

Pakkimistase 1 3389110575866
Pakkimistase 2 3389110575864
Pakkimistase 3 3389110575866

Allalaadimised

Kirjeldus

TeSys LR97D electronic overcurrent relay, 25A/690V, to be supplied with 24V AC/DC, for protection of motors with a rated current 5-21A. It provides 3 dials to adjust the protection, LOAD (5-25A) for the overcurrent level, O-TIME (0.3-10sec) for the acceptable duration of the overcurrent, D-TIME (0.5-30sec) for the starting duration. In addition, the device trips when the current is higher than 3 x LOAD during more than 0.5sec in steady state and if there is a missing phase during more than 3sec. Settings also include selectors for 1-phase/3-phase motors and manual/automatic reset, the device has a reset button, a test/stop button, 2 LED indicators (Run/Trip), 2 auxiliary contacts 1NO/NC for fault signaling. Settings can be locked by sealing the transparent cover. For direct attachment to the bottom terminals of a 3-phase contactor LC1D09-D38, with screw clamp terminals on bottom, the separate mounting from the contactor is possible using the terminal block LAD7B106 (to be ordered separately). Multi-standards certified (IEC, UL, CSA, CCC, EAC), compliant RoHs/Reach.