Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Impulse switch, 1 NO contact + 1 NC contact 16A |
Bränd |
ELTAKO
|
Kategooriad |
Releed
|
Päritoluriik |
CN |
Harmoneeritud süsteemi kood |
8536 5080 00
|
Paigaldusviis |
DIN liist |
Funktsioon |
Elektrooniline lüliti |
Sisseehitussügavus |
58 mm |
Laius mooduli arvudes |
1 |
Juhtpinge 1 |
8-230 V |
Juhtpinge 2 |
230 V |
Juhtpinge 1 liik |
AC/DC |
Juhtpinge 2 liik |
AC |
Juhtpinge 1 sagedus |
50 Hz |
Juhtpinge 2 sagedus |
50 Hz |
Käsitööriist |
No |
Suurim lülitusvool (cos phi = 0.6) |
4 A |
Suurim hõõglampide koormus |
2000 W |
Suurim luminofoorlampide koormus |
1000 VA |
Suurim luminofoorlampide koormus (kaks ahelat) |
1000 VA |
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) |
500 VA |
Tunnuslülitusvool |
16 A |
Normaalselt suletud kontaktide arv |
1 |
Normaalselt avatud kontaktide arv |
1 |
Ümberlülituskontaktide arv |
0 |
Pakendamise üksikasjad
Pakkimistase 1 |
4010312108055, 4010312108055 |
Pakkimistase 2 |
4010312108055 |
Pakkimistase 3 |
4010312108055 |
Allalaadimised
Kirjeldus
1 NO contact + 1 NC contact potential free 16A/250V AC. 230V LED lamps up to 200W, incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Either universal control voltage 8 to 230V UC at the control input +A1/A2 or 230V with glow lamp current up to 5mA at the control input (L)/-A2(N). The simultaneous use of two potentials at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no standby loss. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. Same terminal connection as the electromechanical impulse switch S12-110-. If this impulse switch is in a circuit, which is monitored by a FR12-230V mains disconnection relay, no additional base load is required. However, the monitoring voltage of the FR12-230V must be set to max. The electronics does not have an internal power supply and therefore no power is consumed in any contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.