Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Impulse switch, 2 NO contacts 16A image 1

Impulse switch, 2 NO contacts 16A

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
37,11 €
Hind kehtib kuni 31.12.24
EAN: 4010312108048
MPN: 21200002
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Impulse switch, 2 NO contacts 16A
Bränd ELTAKO
Kategooriad Releed
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Funktsioon Elektrooniline lüliti
Sisseehitussügavus 58 mm
Laius mooduli arvudes 1
Juhtpinge 1 8-230 V
Juhtpinge 2 230 V
Juhtpinge 1 liik AC/DC
Juhtpinge 2 liik AC
Juhtpinge 1 sagedus 50 Hz
Juhtpinge 2 sagedus 50 Hz
Käsitööriist No
Suurim lülitusvool (cos phi = 0.6) 4 A
Suurim hõõglampide koormus 2000 W
Suurim luminofoorlampide koormus 1000 VA
Suurim luminofoorlampide koormus (kaks ahelat) 1000 VA
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) 500 VA
Tunnuslülitusvool 16 A
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 2
Ümberlülituskontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 4010312108048, 4010312108048
Pakkimistase 2 4010312108048
Pakkimistase 3 4010312108048

Allalaadimised

Kirjeldus

2 NO contacts potential free 16A/250V AC. 230V LED lamps up to 200W, incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Either universal control voltage 8 to 230V UC at the control input +A1/A2 or 230V with glow lamp current up to 5mA at the control input (L)/-A2 (N). The simultaneous use of two potentials at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no standby loss. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. Same terminal connection as the electromechanical impulse switch S12-200-. Maximum current across both contacts 16A for 230V. If this impulse switch is in a circuit, which is monitored by a FR12-230V mains dis­connection relay, no additional base load is required. However, the monitoring voltage of the FR12-230V must be set to max. The electronics does not have an internal power supply and therefore no power is consumed in any ­contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.