Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Impulse switch, 1 NO contact 16 A image 1

Impulse switch, 1 NO contact 16 A

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
37,50 €
Hind kehtib kuni 24.12.24
EAN: 4010312107959
MPN: 21100002
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Impulse switch, 1 NO contact 16 A
Bränd ELTAKO
Kategooriad Releed
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Funktsioon Elektrooniline lüliti
Sisseehitussügavus 58 mm
Laius mooduli arvudes 1
Juhtpinge 1 8-230 V
Juhtpinge 2 230 V
Juhtpinge 1 liik AC/DC
Juhtpinge 2 liik AC
Juhtpinge 1 sagedus 50 Hz
Juhtpinge 2 sagedus 50 Hz
Käsitööriist No
Suurim lülitusvool (cos phi = 0.6) 4 A
Suurim hõõglampide koormus 2000 W
Suurim luminofoorlampide koormus 1000 VA
Suurim luminofoorlampide koormus (kaks ahelat) 1000 VA
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) 500 VA
Tunnuslülitusvool 16 A
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 1
Ümberlülituskontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 4010312107959, 4010312107959
Pakkimistase 2 4010312107959
Pakkimistase 3 4010312107959

Allalaadimised

Kirjeldus

1 NO contact potential free 16A/250V AC. 230V LED lamps up to 600W, incandescent lamp load up to 2000W. No standby loss. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. With the patented Eltako Duplex technology (DX) the normally potential-free contacts can still switch in zero passage when switching 230V AC 50Hz and therefore drastically reduce wear. Simply connect the neutral conductor to the terminal (N) and L to 1(L) for this. This results in an standby consumption of only 0.1 watt. If the contact is used for controlling switching devices which do not perform zero passage switching themselves, (N) should not be connected because the additional closing delay otherwise causes the opposite effect. Either universal control voltage 8 to 230V UC at the control input +A1/A2 or 230V with glow lamp current up to 5mA at the control input (L)/-A2 (N). The simultaneous use of two potentials at the control inputs is not permitted. Very low switching noise. No permanent power supply necessary, therefore no standby loss. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. By using a bistable relay coil power loss and heating is avoided even in the on mode. The relay contact can be open or closed when putting into operation. It will be synchronised at first operation. Same terminal connection as the electromechanical impulse switch S12-100-. If this impulse switch is in a circuit, which is monitored by a FR12-230V mains dis­connection relay, no additional base load is required. However, the monitoring voltage of the FR12-230V must be set to max. Control only through A1-A2. The electronics does not have an internal power supply and therefore no power is consumed in any ­contact position. A control current flows only during a short control impulse of 0.2 seconds. This activates the microcontroller, reads the last switching state from the non-voltage memory, switches the bistable relay to its opposite state accordingly and rewrites the new switching state to memory.