Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Impulse switch with integrated relay function, 1 NO contact 10A |
Bränd |
ELTAKO
|
Kategooriad |
Releed
|
Päritoluriik |
CN |
Harmoneeritud süsteemi kood |
8536 5080 00
|
Paigaldusviis |
Süvistatud paigaldus (krohvi) |
Funktsioon |
Elekrooniline, vabastuse viivitusega |
Sisseehitussügavus |
58 mm |
Laius mooduli arvudes |
1 |
Juhtpinge 1 |
8-230 V |
Juhtpinge 2 |
10-230 V |
Juhtpinge 1 liik |
AC |
Juhtpinge 2 liik |
DC |
Juhtpinge 1 sagedus |
50 Hz |
Juhtpinge 2 sagedus |
50 Hz |
Käsitööriist |
No |
Toitepinge liik |
AC/DC |
Toitepinge |
230 V |
Suurim hõõglampide koormus |
2000 W |
Suurim luminofoorlampide koormus |
1000 VA |
Suurim luminofoorlampide koormus (kaks ahelat) |
1000 VA |
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) |
500 VA |
Tunnuslülitusvool |
10 A |
Normaalselt suletud kontaktide arv |
0 |
Normaalselt avatud kontaktide arv |
1 |
Ümberlülituskontaktide arv |
0 |
Pakendamise üksikasjad
Pakkimistase 1 |
4010312107911, 4010312107911 |
Pakkimistase 2 |
4010312107911 |
Pakkimistase 3 |
4010312107911 |
Allalaadimised
Kirjeldus
1 NO contact not potential free 10A/250V AC. 230V LED lamps up to 600W, incandescent lamp load up to 2000W. Off delay impulse switch with switch-off early warning and pushbutton permanent light switchable. Standby loss 0.7 watt only. For installation. 45mm long, 45mm wide, 18mm deep. Zero passage switching to protect contacts and lamps. State-of-the-art hybrid technology combines advantages of nonwearing electronic control with high capacity of special relays. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. Control voltage 230V. In addition electrically isolated universal control voltage from 8 to 230V UC. Supply voltage and switching voltage 230V. Very low switching noise. Variable time range up to 120 minutes in the function ESV. At the control input pushbuttons with a glow lamp current up to 50mA can be connected. In case of a power failure the system is disconnected in a preset sequence. If the timing period is set to minimum in the function ESV, the release delay is switched off. The standard impulse switch function ES is then set. The function ER is selectable. If the function ER is selected a glow lamp current is not permitted. Only the control input A1-A2 should be used. When set to the function ER this device is suitable to feed back the switching voltage signal of a dimmer switch. If switch-off early warning function is switched on, the light starts flickering approx. 30 seconds before time-out. This is repeated three times at decreasing time intervals. If the permanent light function is switched on, the function can be activated by pressing the pushbutton for longer than 1 second. This function switches off automatically after 2 hours or by pressing the pushbutton for longer than 2 seconds. If both switch-off early warning function and permanent light by pushbutton are set, the switch-off early warning function is activated before switching off the permanent light.