Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
RS485 bus universal dimmer switch image 1

RS485 bus universal dimmer switch

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
61,02 €
Hind kehtib kuni 31.12.24
EAN: 4010312313749
MPN: 30014005
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi RS485 bus universal dimmer switch
Bränd ELTAKO
Kategooriad Andurid
Päritoluriik CN
Harmoneeritud süsteemi kood 8526 9200 00
Paigaldusviis DRA (DIN liistule)
Mudel Hämardi
Väljundite arv 1
Sagedus 50 Hz
Siinisüsteem KNX No
Raadiosageduslik siinisüsteem Yes
Siinisüsteem Powernet No
Siiniühendusega Yes
Koormuse liik Universaalne
Suurim juhtimisvool 1 mA
Pinge 230 V
Laius mooduli arvudes 1
Muud siinisüsteemid Puudub
Siinisüsteem LON No
Alajaama sisend No
Võimalik on paralleelne hooldus No
Lokaaljuhtimine/käsijuhtimine Yes
Väljundvõimsus 400 W
Kaitseaste (IP) IP20
LED näidikuga No
Võimendus on võimalik No
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline Yes
Eemaldatav siini moodul Yes
Max. switching power LED 400 W

Pakendamise üksikasjad

Pakkimistase 1 4010312313749, 4010312313749
Pakkimistase 2 4010312313749
Pakkimistase 3 4010312313749

Allalaadimised

Kirjeldus

Universal dimmer switch, Power MOSFET up to 400W. Automatic lamp detection. Bidirectional. Only 0.3 watt standby loss. With adjustable minimum brightness or maximum brightness and dimming speed. With switching operation for light alarm clocks, children's rooms and snooze function. Also with light scene control and constant light regulation. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. The delivery includes a spacer DS14, 1 short jumper 1 module (up to 200W load) and 1 long jumper 1.5 modules (from 200W load with DS14 on the left side). Universal dimmer switch for lamps up to 400W, depending on ventilation conditions, dimmable 230V LED lamps and dimmable energy saving lamps (ESL) are also dependent on the lamp electronics and the dimming technology. Zero passage switching with soft ON and soft OFF to protect lamps. Switching voltage 230V. No minimum load. The brightness level is stored on switch-off (memory). In case of a power failure the switch position and the brightness stage are stored and may be switched on when the power supply is restored. Automatic electronic overload protection and overtemperature switch-off. Connection to the Eltako-RS485 bus. Bus cross wiring and power supply with jumper. The upper rotary switch LA/LRN is first required for teach-in and defines in operation whether automatic lamp detection should be activated or special comfort positions: AUTO allows all lamp types to be dimmed. LC1 is a comfort position for dimmable 230 V LED lamps which cannot be dimmed down far enough in AUTO (phase cut-off) due to their design. LC2 and LC3 are comfort positions for dimmable 230 V LED lamps like LC1 but with different dimming curves. LC4, LC5 and LC6 are comfort positions for LED lamps such as AUTO but with different ­dimming curves. EC1 is a comfort position for energy saving lamps which must be switched on at high voltage due to their design so that they can be dimmed down and switched back on safely when cold. EC2 is a comfort position for energy saving lamps which cannot be switched back on in dimmed-down position due to their design. Therefore the memory is switched off in this position. In positions LC1, LC2, LC3, EC1 and EC2 no inductive (wound) transformers may be used. In addition the maximum number of dimmable LED lamps may be lower than in AUTO position due to their design. PCT is a position for special functions which are set up using the PC tool PCT14. The minimum brightness (fully dimmed down) is adjustable with the middle % lamp rotary switch. The dimming speed is adjustable using the bottom dimming speed rotary switch. The pushbuttons can be taught-in either as direction pushbuttons or universal pushbuttons: When installed as a direction pushbutton, one side is then switch on and dim up and the other side is switch off and dim down. A double-click on the switch-on side activates automatic dim-up to full brightness at dim speed. A double click on the switch-off side activates the snooze function. The children's room function is implemented on the switch-on side. As a universal pushbutton, change the direction by briefly releasing the pushbutton. For light scene control, constant light regulation, light alarm circuit, children‘s room circuit and sleep timer, refer to the operating instructions. When the pushbutton is taught in as a staircase pushbutton, it is possible to retrieve a resettable stair­case time switch function with RV = 2 minutes. Individual light scene pushbuttons can be used to retrieve brightness settings carried out during teach-in. A taught-in FAH can be used to implement a twilight switch. Switch-on can take place using up to 4 FBHs depending on motion and brightness. The LED performs during the teach-in process according to the operating instructions. It shows control commands by short flickering during operation.