Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC image 1
MD99 image 2
HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC image 3
HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC image 4
HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC thumbnail 1
MD99 thumbnail 2
HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC thumbnail 3
HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC thumbnail 4

HCC/S2.1.2.1 Heating/Cooling Circuit Controller, 2-f, 0-10 V, man. op., MDRC

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
280,90 € tk kohta
Hind kehtib kuni 17.01.25
EAN: 4016779011631
MPN: 2CDG110220R0011
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi HCC/S2.2.1.1 Heating/Cooling Circuit Controller, 2-fold, 3-point, MDRC
Bränd ABB
Kategooriad Andurid
Harmoneeritud süsteemi kood 8537 1091 00
Paigaldusviis DRA (DIN liistule)
Väljundite arv 4
Suurim väljundvool 5 A
Suurim lülitusvool (aktiivkoormus) 5 A
Siinisüsteem KNX Yes
Raadiosageduslik siinisüsteem No
Siinisüsteem Powernet No
Siiniühendusega Yes
Digitaalsisendite arv 0
Laius mooduli arvudes 8
Muud siinisüsteemid Puudub
Siinisüsteem LON No
Lülituspinge 230 V
Kaitseaste (IP) IP20
Parandusmuutuja consistent Yes
Lülituse korrektsioon Correcting variable switching No
Kaitseklapifunktsioon Valve protection function Yes
Käsitsi aktiveerimine No
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline No
Eemaldatav siini moodul No
Sisseehitatud paigalduskarbi vähim sügavus 64.5 mm

Pakendamise üksikasjad

Pakkimistase 1 4016779011631

Allalaadimised

Kirjeldus

For the control of a heating or cooling circuit. The device has 2 channels, each with two electronic outputs to control a motor-driven mixing valve (3-Point) of a heating or cooling circuit as well as a relay output (5A) to switch the pump of the circuit. Via 3 binary inputs it is possible to monitor the status of the pump (via potential free contacts) and integrate these feedback into the control of the pump. The flow and return flow temperature are measured and used for the calculation of the control value for the valve output in the integrated controller. The set point temperature is received via the KNX bus. By bundling both channels of the device it is also possible to use it for double pump systems The device supports the ABB i-bus Tool for advanced diagnosis and improved commissioning.