Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
FLUKE-1550C Insulation Resistance Tester (5kV) image 1

Digitale isolatieweerstandstester tot max 5KV

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
5 559,23 €
Hind kehtib kuni 31.12.24
EAN: 0095969550918
MPN: 3665021
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi FLUKE-1550C Insulation Resistance Tester (5kV)
Bränd Fluke
Kategooriad Automaatika ja juhtimine
Tööriistad, mõõtevahendid ja kaitse
Päritoluriik US
Harmoneeritud süsteemi kood 9030 3200 00
Toide Aku
Mõõteväärtuste mälu Yes
Näidik Analoog/digitaalne
Isolatsioonitakistuse mõõteulatus 0.2-1000000 MOhm
Väikese takistuse mõõtmine No
Liides Yes
Andmesalvestus Yes
LC näidu taustavalgustus No
Liigpingekaitse testimine Yes
Analoog-histogrammiga kuvar Yes
Nimiteimipinge 100 V No
Nimiteimipinge 1000 V Yes
Nimiteimipinge 250 V Yes
Nimiteimipinge 2500 V Yes
Nimiteimipinge 500 V Yes
Nimiteimipinge 5000 V Yes
Nimiteimipinge on seadistatav No
Pinge mõõtmine Yes
Nimiteimipinge on seadistatav rambifunktsiooniga Yes
Välise pinge tuvastamin OFF-olekus No
Nominal test voltage 10 kV No
Nominal test voltage 15 kV No

Pakendamise üksikasjad

Pakkimistase 1 0095969550918

Allalaadimised

Kirjeldus

Evaluate the trends; eliminate the doubt The Fluke 1550C insulation resistance testing kit offers digital insulation testing up to 5 kV. And with the Fluke Connect wireless app; you can perform tests and collect data from a safe distance. Remote operation lets you spend as little time as possible in potentially hazardous zones. Real-time trending shows a live graph on your phone; rather than a hard-to-read set of changing values. And you can create reports quickly; simply using drag-and-drop – something you won’t find anywhere else. Learn more >> The 1550C Kit can now conduct the entire range of test voltages specified in IEEE 43-2000 with a best in class; 3 year warranty and CAT IV 600 V safety rating. Other useful features: Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup Guard system eliminates the effect of surface leakage current on high-resistance measurements Selectable test voltages in 50 V steps from 250 V to 1000 V; and 100 V steps above 1000 V CAT III 1000 V; CAT IV 600 V safety rating Warning function alerts the user that line voltage is present and gives the voltage reading up to 600 V AC or DC for increased user safety Measurements can be stored in up to 99 memory locations; with each location assigned a unique; user defined; label for easy recall Long battery life gives the user over 750 tests between charges Large digital/analog LCD for easy viewing Capacitance and leakage current measurement Ramp function for breakdown testing Resistance measurements up to 2 TΩ Timer settings up to 99 minutes for timed tests 3-year warranty