Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 image 1
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 image 2
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 image 3
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 image 4
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 thumbnail 1
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 thumbnail 2
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 thumbnail 3
iPRD1 12.5r 1P 20/50kA Ti ps 1+2 thumbnail 4

Acti9 iPRD1 12.5 1P Surge Protection Dev

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
56,38 €
Hind kehtib kuni 24.12.24
EAN: 3606481490193
MPN: A9L16182
Pakend: 1
Karp: 12
Kaubaalus: 576

Technical Information

Toote seisukord Uus
Tootja nimi iPRD1 12.5r 1P 20/50kA Ti ps 1+2
Bränd Schneider Electric
Kategooriad Valgustuskaitse
Päritoluriik CN
Paigaldusviis DIN-latt (paigaldusliist) 35 mm
Pooluste arv 1
Suurusaste 2 mooduli sammu
Pingekaitsetase 1.5 kV
Kaugsignalisatsioon Yes
Suurim kestevpinge AC 350 V
Nimipinge AC 230 V
Nimipinge DC 0 V
Kategooria Tüüp 1 + 2
Pingekaitsenivoo L-N 1.5 kV
Signaal seadme juures Optiline
Suurim kestevpinge DC 0 V
Kaitseaste (IP) IP20
Maksimaalne PV-pinge 0 V
Pingekaitsetase N-PE 1.5 kV
Sisseehitatud varusulavkaitse No
Maksimaalne juhi ristlõige, jäik (jäik, kiuline) 35 mm²
Maksimaalne juhi ristlõige, painduv (peene kiuga) 25 mm²
Juhistikusüsteem DC No
Juhistikusüsteem IT No
Juhistikusüsteem TN No
Juhistikusüsteem TN-C Yes
Juhistikusüsteem TN-S No
Juhistikusüsteem TT No
Juhistikusüsteem Muu No
Juhistikusüsteem TN-C-S No
Max. overcurrent protection device, parallel connection (fuse) 0 A
Max. overcurrent protection device, series connection (fuse) 0 A
Voltage switching spark gap technology No

Pakendamise üksikasjad

Pakkimistase 1 3606481490193
Pakkimistase 2 3606481490190
Pakkimistase 3 3606481490197
Pakkimistase 4 3606481490193

Allalaadimised

Kirjeldus

This Acti9 iPRD1 12.5r surge arrester protects 1P residential and small commercial buildings installations against direct and indirect transient overvoltages. This type 1+2 device autoprotected by an integrated circuit-breaker is recommanded for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. This Acti9 iPRD1 12.5r is compatible with TN-C earthing system. Associated with Compact NSXm H TM80D the breaking capacity is 70kA. The Imax maximum discharge current is 50kA. The In nominal discharge current is 20kA. The Uc maximum continuous operating voltage in common mode is 350VAC between phase and earth. The Up Voltage protection level is 1.5kV type 1+2. The Ue rated operational voltage is 230VAC. The operating frequency is 50Hz. The dimensions are (W) 18mm x (H) 89mm x (D) 69mm. The width in 9mm pitches is 2. The weight is 171g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +80°C. This product is complies with EN 61643-11 2012 and IEC 61643-11 2011 standards.