Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Digital settable sensor relay, 4 OptoMOS image 1

Digital settable sensor relay, 4 OptoMOS

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
51,11 €
Hind kehtib kuni 31.12.24
EAN: 4010312206553
MPN: 22400501
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Digital settable sensor relay, 4 OptoMOS
Bränd ELTAKO
Kategooriad Elektrikilbid
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Laius 36 mm
Funktsioon Anduri moodul
Kõrgus 62 mm
Sügavus 58 mm
Astro programmiga No
Tunnusvool 0.05 A
Kanalite arv 3
Nädalaprogramm No
Kohalolu simulatsioon Yes
Laius mooduli arvudes 1
Juhtpinge 1 8-230 V
Juhtpinge 1 liik AC/DC
Tunnuspinge 8-230 V
Hämardifunktsioonide arv 0
Rühmalüliti No
Suurim lülitusvool (cos phi = 0.6) 0.05 A
Paanikafunktsioon No
Vooluimpulssfunktsioonid, kanalid 0
Kaitseaste (IP) IP20
Keskfunktsioon OUT No
Trepivalgustus ja eelhoiatus No
Universaalsete hämarduskanalite arv 0
Ruloode-/päikesekaitse juhtimine, kanalite arv 3
Tuuleandur 16-4 m/s
Vihmaandur No
Heledusandur 1000-60000 lx
Videvikuandur 1000-60000 lx

Pakendamise üksikasjad

Pakkimistase 1 4010312206553, 4010312206553
Pakkimistase 2 4010312206553
Pakkimistase 3 4010312206553

Allalaadimised

Kirjeldus

Light-twilight rain wind sensor relay, 4 OptoMOS semiconductor outputs 50mA/8..230V UC. Standby loss 0.05–0.5 watt only. Modular device for DIN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Supply voltage 8 to 230V UC. The sensor relay LRW12D evaluates the signals from the light sensor LS, the rain sensor RS and the wind sensor WS and sends appropriate control signals to the downstream EGS12Z-UC or EGS12Z-UC actuators depending on the setting via the display on the front panel. The OptoMOS semiconductor outputs switch the voltage applied to the universal voltage input terminal +B1. A light sensor LS, rain sensor RS and wind sensor WS can be connected to a sensor relay LRW12D. However, only one per sensor. If one or two of the three possible sensors are not connected, OFF has to be selected in the function menu for the relevant sensor. However, at a wind sensor WS several LRW12D can be connected for controlling different wind speeds. Then the LRW12D must be connected to the same potential +B1/-A2. When the supply voltage UC (8-253V AC or 10-230V DC) is applied to B1/A2, the LRW12D can be set as described in the operating instructions.