Technical Information
Toote seisukord |
Uus |
Tootja nimi |
Analogue settable multifunction time relay, 1 NO contact 10A |
Bränd |
ELTAKO
|
Kategooriad |
Releed
|
Päritoluriik |
CN |
Harmoneeritud süsteemi kood |
8536 5080 00
|
Paigaldusviis |
DIN liist |
Funktsioon |
Mitmeotstarbeline |
Kõrgus |
58 mm |
Aktiveerimismoodus |
Analoog, multifunktsionaalne |
Laius mooduli arvudes |
1 |
Ümberlülitite arv |
0 |
Juhtpinge 1 |
230 V |
Juhtpinge 1 liik |
AC |
Juhtpinge 1 sagedus |
50 Hz |
Toitepinge liik |
AC |
Toitepinge |
230 V |
1. intervalliüksus |
Minutit/tundi |
1. intervall |
0.1-40 |
Nimilülitusvool pingel 250 V AC |
10 A |
Hõõglampide lülitusvõime |
1000 W |
Luminofoorlampide lülitusvõime DUO |
500 VA |
Luminofoorlampide lülitusvõime, induktiivkoormus |
500 VA |
Luminofoorlamide lülitusvõime, rööpühenduses |
250 VA |
Normaalselt suletud kontaktide arv |
0 |
Normaalselt avatud kontaktide arv |
1 |
Pakendamise üksikasjad
Pakkimistase 1 |
4010312603147, 4010312603147 |
Pakkimistase 2 |
4010312603147 |
Pakkimistase 3 |
4010312603147 |
Allalaadimised
Kirjeldus
1 NO contact potential free 10A/250V AC. 230V LED lamps up to 200W, incandescent lamps 1000W*. Standby loss 0.4 watt only. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Control voltage 230V. Supply voltage same as control voltage. Time setting between 0.1 second and 40 hours. Functions F: RV = off delay. AV = operate delay. TI = clock generator starting with impulse. TP = clock generator starting with pause. IA = impulse controlled operate delay (e.g. automatic door opener). EW = fleeting NO contact. AW = fleeting NC contact. ARV = operate and release delay. ON = permanent ON. OFF = permanent OFF. The LED below the big rotary switch indicates the contact position while time-out is in progress. It blinks while the relay contact is open, and is continuously ON as long as the relay contact is closed. The time base T is selected by means of the middle, latching rotary switch T. Time-base figures available are 0.1 seconds, 0.5 seconds, 2 seconds, 5 seconds, 1 minute, 2 minutes, 5 minutes, 1 hour, 2 hours and 4 hours. The total time is obtained by multiplying the timebase by the multiplier. The multiplier xT is set on the upper, latching rotary switch xT and is in the range from 1 to 10. Thus, time settings can be selected in the range from 0.1 second (time base 0.1 second and multiplier 1) and 40 hours (time base 4 hours and multiplier 10). * The maximum load can be used starting at a delay time or clock cycle of 5 minutes. The maximum load will be reduced for shorter times as follows: up to 2 seconds 15%, up to 2 minutes 30%, up to 5 minutes 60%.