Register to unlock your exclusive B2B prices. Register now
MD01 image 1
Miniature circuit-breaker, Acti9 NG125A, 3P, 100 A, C curve, 16 kA (IEC 60947-2) image 2
Miniature circuit-breaker, Acti9 NG125A, 3P, 100 A, C curve, 16 kA (IEC 60947-2) image 3
Miniature circuit-breaker, Acti9 NG125A, 3P, 100 A, C curve, 16 kA (IEC 60947-2) image 4

Miniature circuit-breaker, Acti9 NG125A, 3P, 100 A, C curve, 16 kA (IEC 60947-2)

Laohinnas (käibemaksuta):
153,55 €
Hind kehtib kuni 2024-12-24
Hind m kohta: 153,55 €
EAN: 3303430186045
MPN: 18604
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 18 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Bränd Schneider Electric
Kategooriad Kaitselülitid
Harmoneeritud süsteemi kood 8536 2090 90
Pinge liik AC/DC
Sisseehitussügavus 47 mm
Tunnusvool 100 A
Tunnuspinge 400 V
Sagedus 50-60 Hz
Vabasti tunnusjoon C
Isolatsiooni nimipinge Ui 690 V
Voolupiirangu klass 0
Liigpinge kategooria 4
Saasteaste 3
Laius mooduli arvudes 4.5
Plahvatuskindel No
Kaitseaste (IP) IP20
Kaitstud pooluste arv 3
Samaaegselt lülitatakse N-neutraaljuhti No
Ühendatava juhi ristlõige, massiivsoonega 16-70 mm²
Ühendatava juhi ristlõige, mitmekiuline 10-50 mm²
Talitlusaegne ümbrustemperatuur -30-70 °C
Süvistatud paigaldus No
Lisaseadmed on võimalikud Yes
Pooluste arv (kokku) 3
Lühisvoolu tunnuslahutusvõime Icn standardi EN 60898 järgi pingel 400 V 0 kA
Lühisvoolu tunnuslahutusvõime Icn standardi EN 60898 järgi pingel 230 V 0 kA
Lühisvoolu tunnuslahutusvõime Icu standardi EN 60947-2 järgi pingel 230 V 16 kA
Lühisvoolu tunnuslahutusvõime Icu standardi EN 60947-2 järgi pingel 400 V 16 kA
Tunnus-impulsstaluvuspinge Uimp 8 kV
Pakendamise üksikasjad
Pakkimistase 1 3303430186045
Pakkimistase 2 3303430186043
Downloads
Kirjeldus
This Acti9 NG125a product is a low voltage circuit breaker. It is a 3P circuit breaker with 3 protected poles and 100A In rated current and C tripping curve. The rated short circuit breaking capacity goes up to 16kA at 380VAC to 415VAC conforming to EN/IEC 60947-2 standard. It complies with both industrial standard EN/IEC 60898-1 and residential standard EN/IEC 60947-2. This miniature circuit breaker protects circuits against short circuit and overload current. It is suitable for isolation in the industrial sector according to IEC/EN 60947-2 standard. The fault tripping is indicated by a red mechanical state indicator light on the front face of the circuit breaker. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is equal or below 375VDC, 220VAC to 240VAC, 380VAC to 415VAC, 440VAC or 500VAC. The Ui rated insulation voltage is 690VAC. The Uimp rated impulse withstand voltage is 8kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Its width is 9 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 81mm x (H) 103mm x (D) 81mm. The weight is 0.72kg. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is -30°C to 70°C. The storage temperature is -40°C to 70°C.