Register to unlock your exclusive B2B prices. Register now
Multifunction sensor relay, 5 OptoMOS image 1

Multifunction sensor relay, 5 OptoMOS

Laohinnas (käibemaksuta):
62,91 €
Hind kehtib kuni 2024-12-31
Hind m kohta: 62,91 €
EAN: 4010312205327
MPN: 22500501
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 1 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Multifunction sensor relay, 5 OptoMOS
Bränd ELTAKO
Kategooriad Elektrikilbid
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 4900 00
Paigaldusviis DIN liist
Laius 36 mm
Funktsioon Ilmastikuandurid
Kõrgus 62 mm
Sügavus 58 mm
Astro programmiga No
Tunnusvool 0.05 A
Kanalite arv 5
Nädalaprogramm No
Kohalolu simulatsioon Yes
Laius mooduli arvudes 2
Juhtpinge 1 24 V
Juhtpinge 1 liik DC
Ajapiirkond 5-15 min
Tunnuspinge 24 V
Rühmalüliti No
Paanikafunktsioon No
Kaitseaste (IP) IP20
Keskfunktsioon OUT -
Trepivalgustus ja eelhoiatus No
Keskfunktsioon, kanalite arv 3
Tuuleandur 16-4 m/s
Vihmaandur Yes
Temperatuuriandur 0 °C
Heledusandur 1000-60000 lx
Videvikuandur 1000-60000 lx
Pakendamise üksikasjad
Pakkimistase 1 4010312205327, 4010312205327
Pakkimistase 2 4010312205327
Pakkimistase 3 4010312205327
Downloads
Kirjeldus
Multifunction sensor relay for brightness, twilight, wind, rain and frost, 5 OptoMOS semiconductor outputs 50mA/8..230V UC. Standby loss without Multi sensor MS 0.5 watt only. Modular device for DIN 60715 TH35 rail mounting. 2 modules = 36mm wide, 58mm deep. The multi-sensor relay MSR12-UC evaluates the signals from the multisensor MS once per second, and sends appropriate control signals to the downstream EGS12Z-UC or EGS12Z2-UC actuators depending on the setting of the rotary switch on the front. The OptoMOS semiconductor outputs switch the voltage applied to the universal voltage input terminal +B1. Only a single Multisensor MS can be connected to a Multifunction sensor relay MSR12-UC. Several MSR12-UC can be connected to a multisensor MS, e.g. for evaluating up to three directions with the light sensor of the MS. Only a single MSR12-UC must provide the outer terminal resistance. It must be removed if there is a further MSR12-UC. Supply voltage 24V DC from power unit SNT12-230V/24V DC. This power unit simultaneously supplies the multisensor MS connected to the terminals MS1, MS2, MSA and MSB, including heating of the rain sensor surface. After installation wait for the short automatic synchronisation of approx. 1 minute. During this process three LEDs flash in a slow sequence. Function rotary switches: BA = Setting the operating modes 1 to 10 from the adjacent table. 2 delay times RV - for wind and twilight - each in connection with 5 brightness ranges for light and twilight. The LED behind the rotary switch indicates Frost when the outdoor temperature drops below 2°C, at which point output 6 closes. This output opens again as soon as the temperature is over 3°C for 5 minutes. O-S-W = If the Multisensor MS is aligned towards the south, the weighting for light and twilight can be shifted towards the east or west. lf the MS is mounted in a different direction, the desired point of the compass can be set using this rotary switch. An LED behind the rotary switch indicates rain detection, at which point output 4 closes. Once the rain sensor surface dries out - assisted by a heating unit - contact 4 opens immediately. This is automatically followed by a 2-second pulse on output 2 if the sun signal is applied at that moment. m/s = This rotary switch is used to select the wind speed in metres per second at which the wind signal is triggered. This closes output 5. This is indicated by the LED behind the rotary switch. Opening takes place after the set delay time RV, during which the LED flashes. This is automatically followed by a 2-second pulse on output 2 if the sun signal is applied at that moment. DSR = In this position of the wind rotary switch the MSR12-UC functions like a twilight sensor relay. The twilight signal as described under Lux is then continuously applied to output 3 as long as the set twilight value is undershot. Output 3 opens with a delay of 5 minutes if the brightness value set is overshot. The outputs 4 (rain) and 6 (frost) remain active as described there. Output 5 (wind) likewise remain active, but the wind signal is triggered at 10m/s. TEST = As long as TEST remains switched on, each switchover from the OFF position to the TEST position activates the outputs 2 to 6 in ascending order. OFF = In the OFF position the MSR12-UC has no function. Lux = This rotary switch is used to set the brightness at which the sun signal is immediately triggered as a 2-second pulse at output 2. The LED behind the rotary switch indicates when the brightness value is exceeded. Lux = This rotary switch is used to set the brightness at which the 2-second twilight signal is triggered at output 3 after the set delay time RV when the value is undershot. This is indicated by the LED behind the rotary switch. It flashes during the delay time. If the twilight switching threshold is set to the same level or higher than the sun switching threshold, then the sun switching threshold is raised internally above the twilight switching threshold. Changing light compensation: Constant changes between sun and rain clouds would result in sensitive closing and opening of the shade elements. This is prevented by a changing light compensation function. Sensor function and open circuit monitoring: The Multisensor MS sends updated information to the MSR12-UC every second. If this signal is missing completely for 5 seconds, or if the individual signal from the wind sensor is missing for 24 hours, then an alarm is triggered: three LEDs flash rapidly and the wind output 5 is closed for 2 seconds in order to protect any awnings or windows which may be connected here. This pulse is repeated every hour. The alarm is turned off automatically when a signal is detected again.