Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
NFB31ERT-14 250-500V50/60HZ-DC Contactor image 1
NFB31ERT-14 250-500V50/60HZ-DC Contactor image 2
NFB31ERT-14 250-500V50/60HZ-DC Contactor image 3
NFB31ERT-14 250-500V50/60HZ-DC Contactor thumbnail 1
NFB31ERT-14 250-500V50/60HZ-DC Contactor thumbnail 2
NFB31ERT-14 250-500V50/60HZ-DC Contactor thumbnail 3

NFB31ERT-14 250-500V50/60HZ-DC Contactor

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
46,95 € tk kohta
Hind kehtib kuni 31.12.24
EAN: 3471523106246
MPN: 1SBH137060R1431
Karp: 1

Technical Information

Toote seisukord Uus
Tootja nimi NFB31ERT-14 250-500V50/60HZ-DC Contactor
Bränd ABB
Kategooriad Modulaarsed lülitid
Harmoneeritud süsteemi kood 8536 4900 00
Normaalselt avatud abikontaktide arv 3
Normaalselt suletud abikontaktide arv 1
Juhtahelate tunnus-toitepinge, AC 50 Hz 250 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 250 V
Juhtahelate tunnus-toitepinge, DC 250 V
Aktiveerimispinge liik AC/DC

Pakendamise üksikasjad

Pakkimistase 1 3471523106246

Allalaadimised

Kirjeldus

The NFB31ERT-14 is a contactor relay complying with the latest railway rolling stock standards and allowing installation in passengers or driver cabins for trains frequently operating tunnels or undergrounds. It is used for switching auxiliary and control circuits. These contactor relays: • include screw terminals for connection with ring tongue ferrules. Non-detachable screw with conic washer on auxiliary terminals for a fast and secure tightening of cables with ring tongue ferrules. • improve the compactness of the installations thanks to reduced dimension and side-by-side mounting requiring less 15% width (without spacing) from -40 °C up to +70 °C • meet all main general and rolling stocks standards: IEC 60947-5-1 and the shocks and vibration withstand conforming to IEC 61373 cat. 1, class B • reach the highest levels in fire and smoke behaviour with compliance to European standard EN 45545-2 (HL2, HL3 hazard levels) in group mounting • reduce train energy with lighter devices and requiring 68% less coil energy consumption in operation • get an electronic coil interface accepting sinusoïdal AC 50/60 Hz control supplies included inside Ucmin.... Ucmax voltage range. Max permitted AC 50/60 Hz control voltage must not be exceeded (see technical data) • include mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 and are side-marked with the "Mechanically Linked" symbol • include a wide range of auxiliary contact blocks for front and side mounting.