Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 1
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 2
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 3
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 4
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 5
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 6
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 7
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 8
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 9
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 10
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog image 11
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 1
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 2
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 3
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 4
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 5
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 6
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 7
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 8
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 9
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 10
NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog thumbnail 11

NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
1 217,22 €
Hind kehtib kuni 24.12.24
EAN: 4015081926435
MPN: 192092
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi NZM2 PXR25 circuit breaker - integrated energy measurement class 1, 100A, 4p, variable, earth-fault protection and zone selectivity, plug-in technolog
Bränd EATON
Kategooriad Kaitselülitid
Päritoluriik RO
Harmoneeritud süsteemi kood 8536 2090 00
Normaalselt avatud abikontaktide arv 0
Normaalselt suletud abikontaktide arv 0
Nominaalne püsivool Iu 100 A
Sisseehitatud alapingevabastiga No
Pooluste arv 4
Liigkoormuskaitse sättepiirkond 40-100 A
Ümberlülituvate abikontaktide arv 0
Tunnuspinge 690 V
Kaitseaste (IP) IP20
Peavooluahela ühenduskoht Ühendus erinevate šassii osadega
Sisseehitatud mootorajam No
Peaahela ühendusviis Muul viisil
Juhtelemendi liik Juhthoob
Saadaval väljalülitusindikaator No
Nimi lahutusvõime lühisel Icu 400 V, 50 Hz korral 70 kA
Lühiajalise viivitusega lühisvabasti seadistuspiirkond 2-10 A
Viivituseta lühisvabasti seadistuspiirkond 2-18 A
Sobib paigaldamiseks DIN liistule No
Integreeritud maaühenduskaitse Yes
Mootorajam, valikuline Yes
Seadme ehitus Sisseehitatud seade pistikühendusega
Valikuline paigaldamine DIN liistule (kübara kujuline, top hat rail) No
Komplektne seade koos kaitseplokiga Yes

Pakendamise üksikasjad

Pakkimistase 1 4015081926435

Kirjeldus

The xEffect NZM...-PX...-TZ circuit breaker range with power expert release (PXR) electronic triggering system covers use cases for full range protection including earth fault protection with only four compact sizes and is suitable for the IEC market. The integrated energy measuring function supplies currents, voltages and active energy (kWh) with accuracy class 1 according to IEC 61557-12. Zone selectivity for extended protection included. Test function and settings via micro USB port directly on the switch. Modular function groups always make mounting flexible and may be supplemented by the comprehensive range of accessories . R.m.s. value measurement and thermal memory.