Technical Information

Toote seisukord Uus
Tootja nimi Reflex iC60N Ti24 10 A 2P curve C integrated control MCB
Bränd Schneider Electric
Kategooriad Kaitselülitid
Päritoluriik ES
Harmoneeritud süsteemi kood 8536 2010 90
Pinge liik AC
Sisseehitussügavus 44.5 mm
Tunnusvool 10 A
Tunnuspinge 415 V
Sagedus 50-60 Hz
Vabasti tunnusjoon C
Pooluste arv 2
Voolupiirangu klass 0
Liigpinge kategooria 4
Saasteaste 3
Laius mooduli arvudes 4.5
Kaitseaste (IP) IP20
Samaaegselt lülitatakse N-neutraaljuhti No
Tunnus-lahutusvõime lühisel EN 60898 0 kA
Tunnus-lahutusvõime lühisel IEC 60947-2 10 kA
Abiseadme lülitusvool 1 A
Nimipinge, abiseade 230 V
Juhtpinge tüüp, abiseadmed AC
Lisavarustuse paigaldamine tarnimisel Kaugjuhtimisajam
Construction size (according to DIN 43880) 3

Pakendamise üksikasjad

Pakkimistase 1 3606480455582
Pakkimistase 2 3606480455580

Allalaadimised

Kirjeldus

This Acti9 Reflex iC60N is a low voltage integrated control circuit breaker. It is a 2P circuit breaker with protected poles, 10 A rated current and C tripping curve. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 220VAC to 240VAC, and 10kA at 380VAC to 415VAC. As a circuit breaker, it protects circuits against short circuit and overload currents, disconnection in the industrial sector. It can control a device remotely by latched and/or impulse-type order according to the 2 operating modes to be chosen by the user. Resetting after a fault is performed manually by the resetting handle. The Ti24 interface allows direct interfacing of the Reflex iC60 with a PLC. It allows to execute remote control, to indicate the state of the control circuit and circuit breaker state information, to connect it to the Acti9 Smartlink thanks to the prefabricated cables. Electrical endurance goes up to 50000 cycles. Mechanical endurance to 50000 cycles. The Ui rated insulation voltage is 500VAC. It can be mounted on DIN rail for modular installation. Its width is 9 modules of 9mm. The product color is white (RAL9003). The dimensions are (W) 81 mm x (H) 84 mm x (D) 77 mm. It has an IP20 degree of protection (as per IEC/EN 60529) on its terminals. It becomes IP40 once in modular enclosure with insulation class II.