Technical Information

Toote seisukord Uus
Tootja nimi Digital settable timer with 2 channels, 1+1 NO contacts 16A
Bränd ELTAKO
Kategooriad Releed
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Laius 18 mm
Kõrgus 82 mm
Sügavus 58 mm
Kontaktide arv 2
Mälukohtade arv 60
Astro programmiga Yes
Kanalite arv 2
Raadio teel juhitav No
Nädalaprogramm Yes
Aastaprogramm No
Kontakti liik Normaalselt avatud kontakt (NO)
GPS (globaalne positsioonimissüsteem) No
Laius mooduli arvudes 1
60 min. programm No
24 tunni programm Yes
Puhkusprogram No
Juhusliku valiku programm Yes
Impulsi programm No
Tsükli programm No
Sünkroniseeritud juhid No
Quartz Yes
Automaatne suve-/talveaja lülitus Yes
Käsitööriist Yes
Lülituste eelvalik No
Toitepinge liik AC/DC
Potentsiaalivaba lülituskontakt Yes
Väline programmeerimine No
Raadio teel juhitav (DCF77) No
Toitepinge 8-230 V
Tunniloendur No
Toitepinge sagedus 50 Hz
Autonoomsus tundides 480
Lühim lülitusaeg, kanal 1 1 min
Lühim lülitusaeg, kanal 2 1 min
Nimilülitusvool pingel 250 V AC 16 A
Tekstjuhised kuvaril Yes
Kaitseaste (IP) IP20
Välise surunupu sisend Yes
Mälukaardiga -
Max. switching power LED 200 W

Pakendamise üksikasjad

Pakkimistase 1 4010312603208, 4010312603208
Pakkimistase 2 4010312603208
Pakkimistase 3 4010312603208

Allalaadimised

Kirjeldus

2-channel timer. 1+1 NO contacts potential free 16A/250V AC. 230V LED lamps up to 600W, incandescent lamps 2000W. With astro function. Only 0.03–0.4 watt standby loss. With display backlighting. Modular device for DIN-EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Patented Eltako Duplex technology (DX) allows you to switch normally potential free contacts in zero passage switching when 230V A/C voltage 50Hz is switched. This drastically reduces wear. To achieve this, simply connect the N conductor to the terminal (N) and L to 1(L) and/or 3(L). This results in an additional standby consumption of only 0.1 watt. In the ON state, the use of bistable relays causes no coil power loss or heating. Up to 60 timer memory locations are freely assigned to the channels. With date and automatic summer/winter time changeover. Ca. 7 days power reserve without battery. Each memory location can be assigned with the astro function (automatic switching after sunrise or sundown), the switch on/off time or a pulsed switching time (which triggers an impulse of 2 seconds). The astro switch on/off time can be changed up to ±2 hours. A time lag of up to ±2 hours influenced by the solstices can be entered additionally. With control input (+A1) for central control ON or OFF with priority. Supply and control voltage for central control 8 to 230V UC. The timer is set using the MODE and SET buttons and a keylock function is provided. The display illumination goes on by pressing on MODE or SET. 20 seconds after you last press MODE or SET, the program returns automatically to normal display and the display illumination goes off. Set language: Every time the power supply is applied, press SET within 10 seconds to set the language and press MODE to confirm. D = German, GB = English, F = French, IT = Italian and ES = Spanish. The normal display then appears: weekday, time, day and month. Rapid scroll: In the following settings, the numerals scroll rapidly when you press and hold down Enter. Release then press and hold down to change the scroll direction. Set clock: Press MODE then at PRG (program) press SET to search for the CLK function. Press MODE to set. In H, press SET to select the hour and press MODE to confirm. In M proceed in the same way to set the minute. Set date: Press MODE then at PRG press SET to search for the DAT function. Press MODE to select. At Y, press SET to select the year and press MODE to confirm. Proceed in the same way at M to set the month and at D to set the day. The last setting in the sequence is MO (weekday) blinking. Press SET to set it and press MODE to confirm. Set geographic position (if astro function is required): you can find a list of German cities at the end of the operating manual. Press MODE then press SET at PRG to search for the POS function. Select by pressing MODE. Press SET at LAT to select the latitute. Select by pressing MODE. Repeat this procedure for LON to select the longitude and press MODE to confirm. Press SET at GMT to select the time zone and press MODE to confirm. If desired a time lag of up to ± 2 hours can be entered at WS (winter solstice) and SS (summer solstice) for both channels. Manual switching ON or OFF with priority: Press MODE and for PRG press SET to search for function INT. Then press MODE to select. For CH press SET to select channel 1 or 2 and press MODE to confirm. Now you can switch between AUT (automatic) and ON or OFF using SET. After confirming with MODE the shift position of the selected channel may change. If the shift position should change automatically when a time program becomes active, AUT (automatic) should be selected again. If MODE is pressed longer than 2 seconds at confirmations the change is saved and the normal display will appear. Summer/winter time changeover: Press MODE then at PRG press SET to search for the SWT function and press MODE to select. Now press SET to switch between ON and OFF. If you select ON, changeover is automatic. Central control ON or OFF with priority at automatic mode (AUT): Press MODE and then SET for PRG (program) to search for the function CIA. Press MODE to select. Then press SET to switch from CON to COF and press MODE to confirm. Switch random mode on/off: Press MODE then at PRG press SET to search for the RND function and press MODE to select. Press SET to set to ON (RND+) or OFF (RND) and press MODE to confirm. When random mode is switched on, all switch-on time points of all channels are shifted at random by up to 15 minutes. Switch-on times are switched earlier and switch-off times are switched later. Entering timer programs: refer to the operating instructions. Enable keylock: Briefly press MODE and SET together and at LCK, press SET to lock. This is displayed by an arrow next to the lock symbol. Disable keylock: Press MODE and SET together for 2 seconds and at UNL press SET to unlock.