Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele image 1
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele image 2
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele image 3
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele image 4
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele image 5
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele image 6
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele thumbnail 1
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele thumbnail 2
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele thumbnail 3
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele thumbnail 4
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele thumbnail 5
Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele thumbnail 6

Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
248,42 €
Hind kehtib kuni 24.12.24
EAN: 4015081922321
MPN: 191719
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Safety contactor, 380 V 400 V: 75 kW, 2 N/O, 2 NC, RDC 24: 24 - 27 V DC, DC operation, Screw terminals, integrated suppressor circuit in actuating ele
Bränd EATON
Kategooriad Modulaarsed lülitid
Päritoluriik RO
Harmoneeritud süsteemi kood 8536 4900 00
Sobib DIN paigalduspaneelidele No
Tunnustalitlusvõimsus, AC-3, 400 V 75 kW
Normaalselt avatud peakontaktide arv 3
Normaalselt suletud peakontaktide arv 0
Normaalselt avatud abikontaktide arv 2
Normaalselt suletud abikontaktide arv 2
Tunnus-talitlusvool Ie, AC-3, 400 V 150 A
Tunnus-talitlusvool Ie, AC-1, 400 V 190 A
Juhtahelate tunnus-toitepinge, AC 50 Hz 0 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 0 V
Juhtahelate tunnus-toitepinge, DC 24 V
Peaahela ühendusviis Kruviühendus
Aktiveerimispinge liik DC
Nimitöövool AC-4, 400 V korral 65 A
Tunnustalitlusvõimsus Ie, AC-4, 400 V 33 kW
Tunnustalitlusvõimsus (NEMA) 93 kW

Pakendamise üksikasjad

Pakkimistase 1 4015081922321

Kirjeldus

Safety contactor, Application: Contactors for Motors, Complete devices up to 170 A, Utilization category: AC-1: Non-inductive or slightly inductive loads, resistance furnaces, NAC-3: Normal AC induction motors: starting, switch off during running, AC-4: Normal AC induction motors: starting, plugging, reversing, inching, Connection technique: Screw terminals, Notes: Also suitable for motors with efficiency class IE3., IE3-ready devices are identified by the logo on their packaging., Description: Auxiliary contact element connected non-detachably with basic device (manual activation not possible). , Rated operational current AC-3 380 V 400 V: Ie= 150 A, Rated operational current AC-1 Conventional free air thermal current, 3 pole, 50 - 60 Hz Open at 40 °C: Ith =Ie= 190 A, enclosed: Ith= 144 A, Rated operational current AC-1 Conventional free air thermal current, 1 pole open: Ith= 400 A, enclosed: Ith= 360 A, Max. rating for three-phase motors, 50 - 60 Hz AC-3 220 V 230 V: P= 48 kW, 380 V 400 V: P= 75 kW, 660 V 690 V: P= 96 kW, Max. rating for three-phase motors, 50 - 60 Hz AC-4 220 V 230 V: P= 20 kW, 380 V 400 V: P= 33 kW, 660 V 690 V: P= 48 kW, Contacts N/O = Normally open: 2 N/O, Contacts N/C = Normally closed: 2 NC , Instructions: Contacts to EN 50 012., integrated suppressor circuit in actuating electronics, with mirror contact., Voltage AC/DC: DC operation