Technical Information
Toote seisukord |
Uus |
Tootja nimi |
swit.act. 2-g 16 A man.act. KNX DRA |
Bränd |
Gira
|
Kategooriad |
Andurid
|
Päritoluriik |
DE |
Harmoneeritud süsteemi kood |
8536 4900 00
|
Paigaldusviis |
DRA (DIN liistule) |
Tunnusvool |
0 A |
Väljundvõimsus |
0 W |
Tunnus-talitluspinge |
NA V |
Siinisüsteem KNX |
Yes |
Raadiosageduslik siinisüsteem |
No |
Siinisüsteem Powernet |
No |
Suurim lülitusvõimsus |
0 W |
Siiniühendusega |
Yes |
Suurim lülituskontaktide arv |
4 |
Digitaalsisendite arv |
NA |
Laius mooduli arvudes |
4 |
Suurim lülitusvool |
0 A |
Muud siinisüsteemid |
Puudub |
Siinisüsteem LON |
No |
C-koormus |
No |
Eri faaside ühendamine |
- |
Lokaaljuhtimine/käsijuhtimine |
Yes |
Kaitseaste (IP) |
IP20 |
LED näidikuga |
No |
Laiendusmoodulitega |
- |
Siinisüsteem KNX radio |
No |
Raadiosageduslik, kahesuunaline |
- |
Eemaldatav siini moodul |
- |
Sisseehitatud paigalduskarbi vähim sügavus |
0 mm |
Max. switching power LED |
NA W |
Pakendamise üksikasjad
Pakkimistase 1 |
4010337058359 |
Kirjeldus
Switching actuator, 2-gang 16 A with manual actuation for KNX DRA plus DRA switching actuators with integrated bus coupler. For switching independently controllable groups of loads. With manual switch for switching over the relay (On Off) parallel or without KNX operation. Multi-phase connection. No additional power supply required. Features: Manual actuation of the relay independent of the bus or switching position indication. NO contact or NC contact operation. Central switching function. Group feedback for reduction of bus load. Active or passive (object can be read out) cyclical feedback function. Feedback can be delayed until after the recovery of bus voltage. Logical linking function for each output. Block function can be parameterised for each channel. As an alternative, forced setting function for each output. Time functions (switch-on off delay, staircase light function – also with advance warning function). Integration in light scenes is possible, eight internal scenes at the most can be parameterised per channel. Memory function for light scenes. Elapsed operating time meter as forward backward counter with limit function (limit can be changed via bus) can be activated for each output. Input monitoring for cyclical updating with safety setting. Reactions in case of bus voltage failure and restoration can be set for each channel following an ETS programming process. Independent switching of the two outputs. Notes : Installation on DIN top-hat rail. VDE approval in accordance with EN 60669-1, EN 60669-2-1.