Register to unlock your exclusive B2B prices. Register now
swit.act. 8-g 16 A man.act. + C-load KNX DRA image 1

swit.act. 8-g 16 A man.act. + C-load KNX DRA

Pole saadaval
EAN: 4010337042273
MPN: 104600
Pakendi kohta: 1 Kasti kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi swit.act. 8-g 16 A man.act. + C-load KNX DRA
Bränd Gira
Päritoluriik DE
Harmoneeritud süsteemi kood 8536 4900 00
Paigaldusviis DRA (DIN liistule)
Tunnusvool 0 A
Väljundvõimsus 0 W
Tunnus-talitluspinge NA V
Siinisüsteem KNX Yes
Raadiosageduslik siinisüsteem No
Siinisüsteem Powernet No
Suurim lülitusvõimsus 0 W
Siiniühendusega Yes
Suurim lülituskontaktide arv 4
Digitaalsisendite arv NA
Laius mooduli arvudes 8
Suurim lülitusvool 0 A
Muud siinisüsteemid Puudub
Siinisüsteem LON No
C-koormus Yes
Eri faaside ühendamine -
Lokaaljuhtimine/käsijuhtimine Yes
Kaitseaste (IP) IP20
LED näidikuga No
Laiendusmoodulitega -
Siinisüsteem KNX radio No
Raadiosageduslik, kahesuunaline -
Eemaldatav siini moodul -
Sisseehitatud paigalduskarbi vähim sügavus 0 mm
Max. switching power LED NA W
Pakendamise üksikasjad
Pakkimistase 1 4010337042273
Kirjeldus
Switching actuator, 8-gang 16 A with manual actuation and current measurement for C-loads, for KNX DRA plus DRA switching actuators with integrated bus coupler. For switching independently controllable groups of loads. With manual switch for switching over the relay (On Off) parallel or without KNX operation. Multi-phase connection. No additional power supply required. Features: Manual actuation of the relay independent of the bus or switching position indication. NO contact or NC contact operation. Central switching function. Group feedback for reduction of bus load. Active or passive (object can be read out) cyclical feedback function. Feedback can be delayed until after the recovery of bus voltage. Logical linking function for each output. Block function can be parameterised for each channel. As an alternative, forced setting function for each output. Time functions (switch-on off delay, staircase light function – also with advance warning function). Integration in light scenes is possible, eight internal scenes at the most can be parameterised per channel. Memory function for light scenes. Elapsed operating time meter as forward backward counter with limit function (limit can be changed via bus) can be activated for each output. Input monitoring for cyclical updating with safety setting. Reactions in case of bus voltage failure and restoration can be set for each channel following an ETS programming process. The switching contacts of the switching actuator, 8-gang, C-load are especially designed for loads with a capacitive character, and therefore conditional, brief, high switch-on currents (see Technical Data). The switching actuator has an integrated current detection. A current measurement can be carried out for each channel. Current detection: Measurement of load current for each channel. Threshold values for load monitoring (e.g. signalling of load failure). Independent switching of the eight outputs. Notes : Installation on DIN top-hat rail. VDE approval in accordance with EN 60669-1, EN 60669-2-1.