Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A image 1
MD01 image 2
MD01 image 3
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A image 4
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A image 5
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A image 6
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A thumbnail 4
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A thumbnail 5
TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A thumbnail 6

TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A

Laos: Ei Hankija laovaru: Jah Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
25,24 €
Hind kehtib kuni 24.12.24
EAN: 3389110230444
MPN: LR2K0308
Pakend: 1
Karp: 41
Kaubaalus: 656

Technical Information

Toote seisukord Uus
Tootja nimi TeSys K - differential thermal overload relays - 1.8...2.6 - class 10A
Bränd Schneider Electric
Kategooriad Modulaarsed lülitid
Päritoluriik CZ
Harmoneeritud süsteemi kood 8536 4900 99
Paigaldusviis Vahetu kinnitamine
Normaalselt avatud abikontaktide arv 1
Normaalselt suletud abikontaktide arv 1
Ümberlülituvate abikontaktide arv 0
Vabasti klass KLASS 10 A
Peaahela ühendusviis Kruviühendus
Maksimaalne nimitööpinge Ue 690 V
Voolu seadistuspiirkond 1.8-2.6 A
Ennistusfunktsiooni sisend No
Automaatne ennistusfunktsioon Yes
Nupplülitiga ennistusfunktsioon Yes

Pakendamise üksikasjad

Pakkimistase 1 3389110230444
Pakkimistase 2 3389110230442
Pakkimistase 3 3389110230444

Allalaadimised

Kirjeldus

TeSys LRK thermal overload relay, 2.6A/690V, thermal setting range 1.8-2.6A, tripping class 10A, for protection of 3-phase motors 0.75kW@400V. Differential device with phase failure and load unbalance detection. It provides a thermal adjustement dial, a manual-automatic reset selector, a test slide switch for simulation of a tripping, reset/stop button, a flag indicator and 2 auxiliary contacts 1NO+1NC for fault signalling. Settings are protected by a transparent cover lockable by sealing. Connection by screw clamp terminals, it connects directly to the bottom terminals of 3-pole contactors LC1K06-K16. Mounting on DIN rail, separated from the contactor, with use of a terminal block LA7K0064 (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHs/Reach).