Register to unlock your exclusive B2B prices. Register now
Staircase time switch, 1 NO contact 16A image 1

Staircase time switch, 1 NO contact 16A

Laohinnas (käibemaksuta):
39,31 €
Hind kehtib kuni 2024-12-31
Hind m kohta: 39,31 €
EAN: 4010312401613
MPN: 23100832
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 1 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Staircase time switch, 1 NO contact 16A
Bränd ELTAKO
Kategooriad Releed
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis DIN liist
Funktsioon Elektrooniline väljalülitamise eelhoiatusega
Sisseehitussügavus 58 mm
Vabastusviivitus 1-12 min
Laius mooduli arvudes 1
Juhtpinge 1 230 V
Juhtpinge 2 8-230 V
Juhtpinge 1 liik AC
Juhtpinge 2 liik AC/DC
Juhtpinge 1 sagedus 50 Hz
Juhistikusüsteem 3 ja 4 juhtmega konfiguratsioon
Väljalülitamise eelhoiatus Vilkumine
Korduv Korduv + pidevvalgus + ajapikendus
Toitepinge liik AC
Toitepinge 230 V
Suurim hõõglampide koormus 400 W
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) 400 VA
Tunnuslülitusvool 1.6 A
Nupplüliti gaaslahenduslambi vool 50 mA
Voolu impulssfunktsioon on valitav Yes
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 1
Ümberlülituskontaktide arv 0
Max. switching power LED 200 W
Pakendamise üksikasjad
Pakkimistase 1 4010312401613, 4010312401613
Pakkimistase 2 4010312401613
Pakkimistase 3 4010312401613
Downloads
Kirjeldus
1 NO contact not potential free 16A/250V AC. 230V LED lamps up to 600W, energy saving lamps ESL up to 200W, incandescent lamps up to 2300W. Control voltage 230V and/or 8..230V UC. Switch-off early warning and permanent light by pushbutton switchable. Standby loss 0.7 watt only. With ESL optimisation and multifunction. Modular device for DIN EN 60715 TH35 rail mounting. 1 module = 18mm wide, 58mm deep. Zero passage switching to protect contacts and lamps. The noiseless electronics do not even bother the sensitive ear – unlike many synchronous motors with mechanical gears. By using a bistable relay coil power loss and heating is avoided even in the on mode. The switched consumer may not be connected to the mains before the short automatic ­synchronisation after installation has terminated. Control voltage, supply voltage and switching voltage 230V. In addition electrically isolated universal voltage from 8 to 230V UC. 3-wire and 4-wire circuits, resettable, with attic lighting if 4-wire circuit. Automatic detection of the method of connection. Glow lamp current up to 50mA, dependent on the ignition voltage of the glow lamps. Precise variable time range from 1 to 30 minutes, settable by minute scale. Permanent light switch with the big rotary switch. If the function TLZ is set, the lighting is switched on again after a power failure provided the set time has not yet elapsed. With double connections for pushbutton and lamp in order to connect either above or below or only below. If switch-off early warning function is switched on, the light starts flickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals. If permanent light by pushbutton is switched on, permanent light can be switched on by pressing the pushbutton longer than 1 second. This is switched off automatically after 60 minutes or by pressing the pushbutton longer than 2 seconds. If both switch-off early warning function and permanent light by pushbutton are switched on, the switch-off early warning function is activated before the permanent light switches off. When energy saving lamps ESL are completely or partially switched, then set the switch-off early warning and the permanent light by pushbutton on the right hand side of the rotary switch. If the function TLZ is selected the time can be extended within the first second after switching on or resetting by pressing the pushbutton repeatedly up to three times (incrementing). Each momentary-contact ­control increments the set time once. With multifunction: The following functions can be selected optionally: ES (impulse switch), ER (relay), ESV (impulse switch with release delay). If the function ESV is set the time ranges (t), which can be set with the middle rotary switch are as follows: 1 = 2min, 2 = 5min, 3 = 10min, 4 = 15min, 6 = 25min, 8 = 35min, 10 = 45min, 12 = 60min, 20 = 90min, 30 = 120min. In this function the impulse switch automatically disconnects after the set delay is timed out, if a manual OFF command has not been given. Switch-off early warning and permanent light by pushbutton can also be switched on in this position. Forgotten permanent light is switched off after 2 hours.