Staircase time switch, 1 NO contact 16A image 1

Staircase time switch, 1 NO contact 16A

Laohinnas (käibemaksuta):
39,38 €
Hind kehtib kuni 2024-12-31
Hind m kohta: 39,38 €
EAN: 4010312401620
MPN: 23100836
Meie ladu: Ei Hankija laovaru: Ei
Pakendi kohta: 1 Kasti kohta: 1 Kaubaaluse kohta: N/A
Tehnilised andmed
Toote seisukord Uus
Tootja nimi Staircase time switch, 1 NO contact 16A
Bränd ELTAKO
Kategooriad Releed
Päritoluriik CN
Harmoneeritud süsteemi kood 8536 5080 00
Paigaldusviis Süvistatud paigaldus (krohvi)
Funktsioon Elektrooniline väljalülitamise eelhoiatusega
Sisseehitussügavus 18 mm
Vabastusviivitus 1-12 min
Laius mooduli arvudes 0
Juhtpinge 1 230 V
Juhtpinge 1 liik AC
Juhtpinge 1 sagedus 50 Hz
Juhistikusüsteem 3 juhtmega konfiguratsioon
Väljalülitamise eelhoiatus Vilkumine
Korduv Korduv + pidevvalgus + ajapikendus
Toitepinge liik AC
Toitepinge 250 V
Suurim hõõglampide koormus 2000 W
Suurim luminofoorlampide koormus 1000 VA
Suurim luminofoorlampide koormus (kaks ahelat) 1000 VA
Suurim luminofoorlampide koormus (rööpkompensatsiooniga) 500 VA
Tunnuslülitusvool 10 A
Nupplüliti gaaslahenduslambi vool 50 mA
Voolu impulssfunktsioon on valitav No
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 1
Ümberlülituskontaktide arv 0
Max. switching power LED 100 W
Pakendamise üksikasjad
Pakkimistase 1 4010312401620, 4010312401620
Pakkimistase 2 4010312401620
Pakkimistase 3 4010312401620
Downloads
Kirjeldus
1 NO contact not potential free 16A/250V AC. 230V LED lamps up to 600W, energy saving lamps ESL up to 200W, incandescent lamps up to 2300W. Switch-off early warning switchable. Standby loss 0.7 watt only. Modular device for DIN EN 50022 rail mounting. 1 module = 18mm wide, 58mm deep. Zero passage switching to protect contacts and lamps. The noiseless electronics do not even bother the sensitive ear - unlike many synchronous motors with mechanical gears. By using a bistable relay coil power loss and heating is avoided even in the onmode. The switched consumer may not be connected to the mains before the short automatic synchronisation after installation has terminated. 230V control voltage, supply voltage and switching voltage. Glow lamp current up to 50mA, dependent on the ignition voltage of the glow lamps. Precise variable time range from 1 to 12 minutes, settable by minute scale. Own permanent light switch with the big rotary switch. 3-wire circuit with attic lighting, not resettable. Only for retrofitting of existing systems. After a power failure the lighting is switched on again in case the set time has not elapsed yet. If switch-off early warning function is switched onthe light starts flickering approx. 30 seconds before time-out and is repeated three times at decreasing time intervals.