Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor image 1
UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor image 2
UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor image 3
UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor thumbnail 1
UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor thumbnail 2
UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor thumbnail 3

UA16-30-10RA 24V 50Hz / 24V 60Hz Contactor

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
40,17 € tk kohta
Hind kehtib kuni 31.12.24
EAN: 3471522300843
MPN: 1SBL181024R8410
Pakend: 1
Karp: 63

Technical Information

Toote seisukord Uus
Tootja nimi UA16-30-10RA 110V 50Hz / 110-120V 60Hz Contactor
Bränd ABB
Kategooriad Modulaarsed lülitid
Harmoneeritud süsteemi kood 8536 4900 00
Normaalselt avatud peakontaktide arv 3
Normaalselt suletud peakontaktide arv 0
Normaalselt avatud abikontaktide arv 1
Normaalselt suletud abikontaktide arv 0
Juhtahelate tunnus-toitepinge, AC 50 Hz 110 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 110-120 V
Peaahela ühendusviis Kruviühendus
Nominaalne pimevõimsus 400 V, 50 Hz korral 12.5 kvar
Aktiveerimispinge liik AC

Pakendamise üksikasjad

Pakkimistase 1 3471522300843
Pakkimistase 2 3471522300843

Allalaadimised

Kirjeldus

The UA16-30-10RA 110V 50Hz / 110-120V 60Hz is a 3-pole contactors for capacitor switching, can be used in installations in which the peak current far exceeds 100 times nominal rms current. The contactors are delivered complete with their damping resistors and must be used without additional inductances (see table below). The capacitors must be discharged (maximum residual voltage at terminals ≤ 50 V) before being re-energized when the contactors are making. Their electrical durability is 250 000 operating cycles for Ue < 500 V and 100 000 operating cycles for 500 V ≤ Ue ≤ 690 V. The UA..RA contactors are fitted with a special front mounted block, which ensures the serial insertion of 3 damping resistors into the circuit to limit the current peak on energization of the capacitor bank. Their connection also ensures capacitor precharging in order to limit the second current peak occurring upon making of the main poles. The insertion of resistors allows to damp the highest current peak of the capacitor when switching on, whatever its level. The UA..RA series 3-pole contactors are of the block type design. - Main poles and auxiliary contacts: 3 main poles, 1 built-in auxiliary contact - Control circuit: AC operated with laminated magnet circuit - Accessories: a wide range of accessories is available.