Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 1
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 2
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 3
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 4
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 5
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 6
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 7
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 8
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 9
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 10
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 11
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 12
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 13
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 14
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 15
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  image 16
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 1
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 2
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 3
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 4
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 5
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 6
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 7
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 8
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 9
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 10
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 11
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 12
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 13
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 14
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 15
Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,  thumbnail 16

Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
80,00 €
Hind kehtib kuni 24.12.24
EAN: 4015081877713
MPN: 189776
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Undervoltage release for NZM2/3, 1 early-make auxiliary contact, 2NO,
Bränd EATON
Kategooriad Tarvikud (automaatika ja juhtimine)
Päritoluriik RO
Harmoneeritud süsteemi kood 8538 9099 00
Viivitusega No
Sobib lahklülitile Yes
Sobib liigkoormusreleele No
Elektriühenduse liik Kruviühendus
Juhtahelate tunnus-toitepinge, AC 50 Hz 60 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 60 V
Juhtahelate tunnus-toitepinge, DC 0 V
Sobib mootorikaitselülitile Yes
Sobib toiteahela kaitselülitiks No
Aktiveerimispinge liik AC
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 1
Ümberlülituskontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 4015081877713

Kirjeldus

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Undervoltage releases with one early-make contact and push-in terminals. For interlocking and load-shedding circuits, as well as for early-make of the undervoltage release in main-switch applications. Non-delayed disconnection of circuit-breaker NZM when control voltage drops below 35 - 70 % Us. For use with emergency switching off devices in conjunction with emergency switching off buttom . When the undervoltage release is de-energized, accidental contact with the main contacts of the circuit-breaker dureing attempts to switch on is reliably prevented. Early-make of auxiliary contacts on switching on and off (manual operation): approx. 20 ms (NZM2/3) and 90 ms (NZM4). Undervoltage release modules cannot be installed simultaneously with early-make contact NZM…-XHIV, shunt release NZM…-XA… or relais modules NZM...-X2A...