Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 1
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 2
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 3
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 4
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 5
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 6
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 7
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 8
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 9
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 10
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 11
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 12
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 13
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 14
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 15
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals image 16
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 1
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 2
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 3
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 4
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 5
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 6
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 7
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 8
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 9
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 10
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 11
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 12
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 13
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 14
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 15
Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals thumbnail 16

Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
76,74 €
Hind kehtib kuni 24.12.24
EAN: 4015081877201
MPN: 189725
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Undervoltage release for NZM2/3, configurable relays, 2NO, 24DC, Push-in terminals
Bränd EATON
Kategooriad Tarvikud (automaatika ja juhtimine)
Päritoluriik RO
Harmoneeritud süsteemi kood 8538 9099 00
Viivitusega No
Sobib lahklülitile Yes
Sobib liigkoormusreleele No
Elektriühenduse liik Vedruklamber ühendus
Juhtahelate tunnus-toitepinge, AC 50 Hz 0 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 0 V
Juhtahelate tunnus-toitepinge, DC 24 V
Sobib mootorikaitselülitile Yes
Sobib toiteahela kaitselülitiks No
Aktiveerimispinge liik DC
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 2
Ümberlülituskontaktide arv 0

Pakendamise üksikasjad

Pakkimistase 1 4015081877201

Kirjeldus

Optional accessories for the circuit-breaker series NZM offers a comprehensive portfolio of application options for use world wide. The mounting is always flexible and easy thanks to the modular function groups. Notes: Undervoltage releases with two relays. Non-delayed disconnection of circuit-breaker NZM when control voltage drops below 35 - 70 % Us. For use with emergency switching off devices in conjunction with emergency switching off buttom. For signalizing commands or different states of the circuit-breaker. Two relays per unit. Actuation reason can be configured in the trip unit . Configuration via communication or circuit breaker display or front USB connection and Eaton Power Xpert Protection Manager. When the undervoltage release is de-energized, accidental contact with the main contacts of the circuit-breaker dureing attempts to switch on is reliably prevented. Only suitable for use in conjunction with circuit-breakers with electronic releases. Undervoltage release relais modules cannot be installed simultaneously with early-make contact NZM…-XHIV, or untervoltage release NZM…-XU…, or shunt release NZM…-XA… Relay coil actuated by trip unit. Relay contact for control wiring. Control wiring to push-in terminals . Cannot be used with PXR10 NZM-AE electronic release.