Registreeru, et avada oma eksklusiivsed B2B hinnad ja alustada ostlemist. Registreeru kohe!
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 1
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 2
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 3
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 4
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 5
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 6
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 7
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 8
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 9
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 10
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 11
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 12
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 13
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter image 14
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 1
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 2
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 3
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 4
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 5
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 6
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 7
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 8
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 9
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 10
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 11
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 12
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 13
Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter thumbnail 14

Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
271,76 €
Hind kehtib kuni 24.12.24
EAN: 4015081707966
MPN: 174334
Pakend: 1

Technical Information

Toote seisukord Uus
Tootja nimi Variable speed starter, Rated operational voltage 400 V AC, 3-phase, Ie 2.1 A, 0.75 kW, 1 HP, Radio interference suppression filter
Bränd EATON
Kategooriad Juhtseadmed
Päritoluriik GB
Laius 45 mm
Kõrgus 230 mm
Sügavus 169 mm
Juhtseadmega No
Digitaalsisendite arv 4
Digitaalväljundite arv 0
Analoogsisendite arv 1
Analoogväljundite arv 0
Tugiprotokoll LON No
Riistvaraliideste tööstuslik Ethernet arv 0
Riistvaraliideste RS-232 arv 0
Riistvaraliideste RS-422 arv 0
Riistvaraliideste RS-485 arv 1
Riistvara jadaliideste TTY arv 0
Riistvaraliideste USB arv 0
Riistvara rööpliideste arv 0
Muude riistvaraliideste arv 0
Optilise liidesega No
Tugiprotokoll TCP/IP No
Tugiprotokoll ASI No
Tugiprotokoll PROFIBUS No
Tugiprotokoll CAN No
Tugiprotokoll INTERBUS No
Tugiprotokoll KNX No
Tugiprotokoll MODBUS Yes
Tugiprotokoll Data-Highway No
Tugiprotokoll DeviceNet No
Tugiprotokoll SUCONET No
Toetab muid andmesideprotokolle Yes
Kaitseaste (IP) IP20
Arvuti PC liidesega Yes
Toetab andmesideprotokolli SERCOS No
Toetab andmesideprotokolli INTERBUS-Safety No
Toitepinge 380-480 V
Võrgusagedus 50/60 Hz
4-se jaotustalitluse tugi No
Riistvaraliideste PROFINET arv 0
Muunduri tüüp Pingemuundur
Faaside arv väljundis 3
Faaside arv sisendis 3
Sisseehitatud pidurdustakisti No
Lubatud on tööstusoludes kasutamine Yes
Lubatud kasutamine kodumajapidamistingimustes Yes
Maksimaalne väljund sagedus 500 Hz
Maksimaalne väljund lineaarkoormusel nimiväljundpingel 0.75 kW
Suurim võimsus ruutkoormusel tunnusväljundpinge korral 0.75 kW
Suhteline sümmeetriline võrgu voolutolerants 10 %
Suhteline sümmeetriline võrgu sagedustolerants 10 %
Toetab andmesideprotokolli AS-Interface Safety at Work No
Toetab andmesideprotokolli DeviceNet Safety No
Toetab andmesideprotokolli EtherNet/IP Yes
Toetab andmesideprotokolli Foundation Fieldbus No
Toetab andmesideprotokolli PROFINET CBA No
Toetab andmesideprotokolli PROFINET IO No
Toetab andmesideprotokolli PROFIsafe No
Toetab andmesideprotokolli SafetyBUS p No
Suurim väljundpinge 500 V
Nimiväljundvool I2N 2.1 A
BACnet'i tugiprotokoll No
Kaitseaste (NEMA) Muul viisil

Pakendamise üksikasjad

Pakkimistase 1 4015081707966

Kirjeldus

Variable speed starters, Part group reference (e.g. DIL): DE1, Rated operational voltage: Ue = 400 V AC, 3-phase, 480 V AC, 3-phase, Output voltage with Ve: U2 = 400 V AC, 3-phase, 480 V AC, 3-phase, Mains voltage (50/60Hz): ULN = 380 (-10%) - 480 (+10%) V, Rated operational current At 150% overload: Ie = 2.1 A, Note: Rated operational current at an operating frequency of 16 kHz and an ambient air temperature of +50 °C, Note: Overload cycle for 60 s every 600 s, Assigned motor rating Note: for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm-1 at 50 Hz or 1800 min-1 at 60 Hz , Overload cycle for 60 s every 600 s, at 400 V, 50 Hz, Assigned motor rating 150 % Overload: P = 0.75 kW, 150 % Overload: IM = 1.9 A, Assigned motor rating Note: at 440 - 480 V, 60 Hz, Assigned motor rating 150 % Overload: P = 1 HP, Assigned motor rating 150 % Overload: IM = 2.1 A, Degree of Protection: IP20/NEMA 0, Interface/field bus (built-in): OP-Bus (RS485)/Modbus RTU, Fitted with: Radio interference suppression filter, Frame size: FS1, Standards: Specification for general requirements: IEC/EN 61800-2, EMC requirements: IEC/EN 61800-3, Safety requirements: IEC/EN 61800-5-1

Sarnane

Tarvik

Sarnane

Tarvik

Sarnane
4015081945221 4015082695002 4015082695392 4015081785100 4015081819980
Tarvik
4015081945221 4015082695002 4015082695392 4015081785100 4015081819980
Sarnane
4015081656189 4015081819980 4015081803903 4015081785391 4015081785452
Tarvik
4015081819980 4015081945221 4015082695002 4015082695392 4015081785100