MD01 image 1

VIGILOHM IM20 - H 110-230 V CA

Laos: Ei Hankija laovaru: Ei Minimaalne tellimuse kogus: 1
Hind (ilma KM-ta):
807,98 €
Hind kehtib kuni 24.12.24
EAN: 3606480321702
MPN: IMD-IM20-H
Pakend: 1
Karp: 8

Technical Information

Toote seisukord Uus
Tootja nimi VIGILOHM IM20 - H 110-230 V CA
Bränd Schneider Electric
Kategooriad Releed
Laius 96 mm
Funktsioon Segasüsteemile
Kõrgus 110 mm
Sügavus 59 mm
Nimisagedus 50-60 Hz
Eemaldatavate klambritega No
Liini võimsus 0 µF
Isolatsioonitakistuse näit Yes
Võimalik on vigade registreerimine Yes
Elektriühenduse liik Kruviühendus
Tunnuspinge 0-230 V
Juhtahelate tunnus-toitepinge, AC 50 Hz 110-230 V
Juhtahelate tunnus-toitepinge, AC 60 Hz 110-230 V
Juhtahelate tunnus-toitepinge, DC 125-250 V
Näivtakistuse 1 väärtus 110 kOhm
Näivtakistuse 2 väärtus 50-500 kOhm
Aktiveerimispinge liik AC
Normaalselt suletud kontaktide arv 0
Normaalselt avatud kontaktide arv 0
Ümberlülituskontaktide arv 1

Pakendamise üksikasjad

Pakkimistase 1 3606480321702
Pakkimistase 2 3606480321709

Allalaadimised

Kirjeldus

This device belongs to the Vigilohm range designed to monitor ungrounded/IT electrical networks, in accordance to installation and products standards. According to IEC standards, it is mandatory to equip IT medical premises with Insulation Monitoring Devices (IMD). This device is dedicated to monitoring AC, DC and ACDC medical IT systems. It mesures the system insulation resistance by injecting a low frequency AC current between the network and ground. Configuration will be set in accordance to medical standards, from the front of the device, through the HMI screen. Setting are related to insulation alarm thresholds from 50 kilohms to 500 kilohms, and Transformer overheat and overload alarms. It monitors networks up to 230VAC, 230VDC, in medical IT architecture, and well as the medical IT transformer. The black and white screen can displays insulation resistance from 100 ohms to 10 megohms. Auto-test starts automatically every 5 hours, and on demand. In case the system insulation resistance drops below the set threshold, meaning a ground fault occurred, an alarm is triggered thru the IMD output relay within 4 seconds. Once no fault is monitored, the alarm is cleared, the alarm relay is back to normal. The device can be supplied by a 110VAC to 230VAC source or a 125VDC to 250VDC, all with a tolérence of plus or minus 15%. This product can be installed on DIN rail, or flush mounted. Front face ingress protection is IP52, rear IP20 and overvolage category III. The monitoring device is equipped with a RS485 communication port, Modbus protocol.