Register to unlock your exclusive B2B prices. Register now
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 1
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 2
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 3
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 4

Control unit 0-10 V REG-K/1-gang with manual mode, light grey

Sandėlyje esančios prekės kaina (be PVM):
158,06 €
Ši kaina galioja iki 2024-09-30
Kaina už m: 158,06 €
EAN: 3606485100043
MPN: MTN647091
Mūsų sandėlis: Ne Pardavėjo atsargos: Ne
Už pakuotę: 1 Už dėžę: 10 Už padėklą: N/A
Techniniai duomenys
Prekės būklė Nauja
Gamintojo pavadinimas Control unit 0-10 V REG-K/1-gang with manual mode, light grey
Prekės ženklas Schneider Electric
Kategorijos Jutikliai
Kilmės šalis DE
Montavimo metodas DRA
Išvesčių skaičius 1
Maks. perjungimo srovė (varžinė apkrova) 16 A
EIB / KNX magistralės sistema Yes
Magistralės sistemos radijo dažnis No
„Powernet“ magistralės sistema No
Maks. perjungimo galia 3600 W
Įtraukta magistralės jungtis Yes
Maks. kontrolinė srovė 100 mA
Modulinių tarpų skaičius plotyje 2.5
Kitos maršrutinės sistemos Nėra
Šviesos daviklių įvesčių skaičius 0
LON magistralinė sistema No
Pastotės įvestis No
Lokali operacija / rankos operacija Yes
Saugos laipsnis (IP) IP20
Su LED rodmeniu No
1-10 V sąsaja Yes
KNX radijo magistralės sistema No
Dvikryptis radijas No
Mažiausias įmontuoto įrenginio gylis 0 mm
Pakavimo informacija
Pakavimo lygis 1 3606485100043
Pakavimo lygis 2 3606485100041
Downloads
Aprašymas
Control unit 0-10 V REG-K/1-gang with manual mode. For connecting devices with 0-10 V interface to KNX. With integrated bus coupler and screw terminals (230 V) or plug-in screw terminals (0-10 V). Each individual 230 V switch output can be operated manually with a manual switch. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. KNX software functions: Different dimming curves and dimming speeds, the same dimming time, memory function, ON/OFF delay, staircase time function with/without manual OFF function. Scenes (up to eight stored brightness values can be retrieved), central function, logic operation or priority control, blocking function, status feedback, behaviour on bus voltage recovery. Switch contact: for switching the electronic ballasts/transformers. Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. Nominal current: 16 A, inductive load cos Phi 0.6. Nominal load: Incandescent lamps: AC 100 V, max. 1600 W. AC 230 V, max. 3600 W. AC 240 V, max. 3840 W. Halogen lamps: AC 100 V, max. 1086 W. AC 230 V, max. 2500 W. AC 240 V, max. 2608 W. Fluorescent lamps: AC 100 V, max. 1086 VA. AC 230 V, max. 2500 VA. AC 240 V, max. 2608 VA. parallel-compensated. Capacitive load: AC 100 V, max. 1600 W, 200 µF. AC 230 V, max. 3600 W, 200 µF. AC 240 V, max. 3840 W, 200 µF. 0-10 V interface: 0.12-100 mA. Voltage range: DC 0-10 V. Device width: 2.5 modules, approx. 45 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.