Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 1
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 2
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 3
Control unit 0-10 V REG-K/1-gang with manual mode, light grey image 4

Control unit 0-10 V REG-K/1-gang with manual mode, light grey

Noliktavas cena (bez PVN):
158,06 €
Šī cena ir spēkā līdz 2024-09-30
Cena par m: 158,06 €
EAN: 3606485100043
MPN: MTN647091
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 10 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Ražotāja nosaukums Control unit 0-10 V REG-K/1-gang with manual mode, light grey
Zīmols Schneider Electric
Kategorijas Sensori
Izcelsmes valsts DE
Montāžas metode DRA (adapteris uz DIN sliedes)
Izvadu skaits 1
Maks. pārslēgšanas strāva (pretestības slodze) 16 A
Autobusu sistēma KNX Yes
Autobusu sistēmas radio bieži No
Autobusu sistēma Powernet No
Maks. pārslēgšanas jauda 3600 W
Ar autobusa savienojumu Yes
Maks. vadības strāva 100 mA
Platums moduļu atstarpju skaitā 2.5
Citas autobusu sistēmas Nav
Gaismas sensora ieeju skaits 0
Autobusu sistēma LON No
Apakšstacijas ieeja No
Vietējā darbība/rokas darbība Yes
Aizsardzības pakāpe (IP) IP20
Ar LED indikāciju No
Interfeiss 1-10 V Yes
Autobusu sistēma KNX radio No
Radio bieži divvirzienu No
Min. iebūvētās instalācijas kastes dziļums 0 mm
Iepakojuma informācija
Iepakojuma līmenis 1 3606485100043
Iepakojuma līmenis 2 3606485100041
Downloads
Apraksts
Control unit 0-10 V REG-K/1-gang with manual mode. For connecting devices with 0-10 V interface to KNX. With integrated bus coupler and screw terminals (230 V) or plug-in screw terminals (0-10 V). Each individual 230 V switch output can be operated manually with a manual switch. For installation on DIN rails TH35 according to EN 60715. The bus is connected using a bus connecting terminal. a data rail is not necessary. KNX software functions: Different dimming curves and dimming speeds, the same dimming time, memory function, ON/OFF delay, staircase time function with/without manual OFF function. Scenes (up to eight stored brightness values can be retrieved), central function, logic operation or priority control, blocking function, status feedback, behaviour on bus voltage recovery. Switch contact: for switching the electronic ballasts/transformers. Nominal voltage: AC 100-240 V ±10%. Operating voltage: min. AC 90 V - max. AC 265 V. Mains frequency: 50-60 Hz ±10%. Nominal current: 16 A, inductive load cos Phi 0.6. Nominal load: Incandescent lamps: AC 100 V, max. 1600 W. AC 230 V, max. 3600 W. AC 240 V, max. 3840 W. Halogen lamps: AC 100 V, max. 1086 W. AC 230 V, max. 2500 W. AC 240 V, max. 2608 W. Fluorescent lamps: AC 100 V, max. 1086 VA. AC 230 V, max. 2500 VA. AC 240 V, max. 2608 VA. parallel-compensated. Capacitive load: AC 100 V, max. 1600 W, 200 µF. AC 230 V, max. 3600 W, 200 µF. AC 240 V, max. 3840 W, 200 µF. 0-10 V interface: 0.12-100 mA. Voltage range: DC 0-10 V. Device width: 2.5 modules, approx. 45 mm. Contents: With bus connecting terminal and cable cover. Colour: light grey.