KA4224Z Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC image 5
MD01 thumbnail 1
MD01 thumbnail 2
MD01 thumbnail 3
MD01 thumbnail 4
KA4224Z Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC thumbnail 5

KA4224Z Mess-u.Wandlerfeld H5/B2

Piegādātāja krājumi: Nē Minimālais pasūtījuma daudzums: 1
Noliktavas cena (bez PVN):
2 359,02 €
Šī cena ir spēkā līdz 24.12.24
EAN: 4011617338758
MPN: 2CPX033875R9999
Kaste: 1

Technical Information

Preces stāvoklis Jauns
Ražotāja nosaukums KA4224Z Measurement and metering transformer board, Field width: 2, Rows: 0, 1350 mm x 500 mm x 160 mm, IP2XC
Zīmols ABB
Kategorijas Sadales paneļi
Harmonizētās sistēmas kods 8537 1098 00
Krāsa Pelēks
Platums 500 mm
Modelis 2-stāvu
Augstums 1350 mm
RAL numurs 7035
Ar montāžas plāksni No
Savienojuma telpa 300 mm
Ar elektroinstalāciju Yes
Platums moduļu atstarpju skaitā 24
TSG paneļu skaits 1
Izplatītāja rindu skaits 0
Skaitītāju skapju skaits 1
Apakšējā savienojuma vieta Ar kopņu joslu 5-polu
Aizsardzības pakāpe (IP) IP2XC
Galvenā slēdža nominālā strāva 160 A
Vāka modelis Slēgts ar iepriekšēju nostiprināšanu

Iepakojuma informācija

Iepakojuma līmenis 1 4011617338758

Lejupielādes

Apraksts

Measurement and metering transformer board, fully assembled module, with Metering cross, for the internal use, degree of protection IP2XC, applicable standards: EN 61439-1, EN 61439-2, Rated operational voltage 415V AC 50/60 Hz, rated current 128 A, Rated current of the assembly of switchgear and controlgear InA 160 A, in RAL 7035, dimensions in mm (H x W x D): 1350 x 500 x 160, Earthing system TN-S, 5-pole, Number of SG spaces 1, Number of transformer meter spaces 1, Pre-wired according requirements DSO, voltage path Fuse base element D01/3-pole sealable, busbar system Cu busbars 12 x 5 mm 5-pole, parting point before the current transformer Fuse switch disconnector NH00/160A, current transformer range CT mounting pad with CT rail 170 x 30 x 5 mm, parting point after the current transformer Switch 160 A / 3-pole (10-70qmm), primary wiring 70 qmm, N+PE Connection N+PE 95qmm, Note: metering transformer sets to be installed in seperate housing. For DSO Cottbus cabinets have to be IP54. Incomer housing could be e.g. EK221, Grid unit 9 GU, Overall height 5, panel width 2, Space units 216, covers out of Plastic, Quick sealable connection, RAL 7035