Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
Three-phase energy meter, without approval |
Zīmols |
ELTAKO
|
Kategorijas |
Elektrības skaitītāji
|
Izcelsmes valsts |
CN |
Harmonizētās sistēmas kods |
9028 3019 00
|
Montāžas metode |
DRA (adapteris uz DIN sliedes) |
Platums |
70 mm |
Augstums |
82 mm |
Dziļums |
58 mm |
Biežums |
50 Hz |
Maks. strāva (Imax) |
80 A |
Platums moduļu atstarpju skaitā |
4 |
Aizsardzības pakāpe (IP) |
IP20 |
Pulss |
1000 Imp/kWh (kvarh) |
Pole tips |
Četru vadītāju |
Nominālais spriegums (Un) NL |
230 V |
Nominālā strāva (in) |
10 A |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010312501719, 4010312501719 |
Iepakojuma līmenis 2 |
4010312501719 |
Citi tehniskie dati
Modelis |
Tiešie mērījumi |
Piemērots |
Iegāde/piegāde |
Norādes veids |
Digitālais |
Kopējais pozīciju skaits (skaitītājs) |
7 |
Skaitītāja veids |
Elektroniskais |
Interfeisa veids |
Citi |
Enerģijas veids |
Efektīva jauda |
Tarifa veids |
Divu tarifu |
Evakuācijas mehānisms |
Yes |
Kalibrēts |
No |
Impulsu izvade |
Optika |
Impulsa veids |
S0 |
Precizitātes klase |
B |
Mērījumu veida slodzes profils |
- |
EEC40 paraksts |
- |
Ar bloķēšanas kodu |
- |
Nominālais spriegums (Un) LL |
400 V |
Lejupielādes
Apraksts
Maximum current 3x80A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. Like all meters without declaration of conformity (e.g. MID), this meter is not permitted for billing. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. Designed as standard for using as double-tariff meter: Switch over to a second tariff by applying 230V to terminals E1/E2. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy per tariff, the active energy per resettable memory RS1 or RS2, and the instantaneous values of consumption, voltage and current per phase. Error message (false): When the phase conductor is missing or the current direction is wrong 'false' and the corresponding phase conductor are indicated on the display.