Technical Information
Preces stāvoklis |
Jauns |
Ražotāja nosaukums |
Two-way three-phase meter, MID calibrated |
Zīmols |
ELTAKO
|
Kategorijas |
Elektrības skaitītāji
|
Izcelsmes valsts |
CN |
Harmonizētās sistēmas kods |
9028 3019 00
|
Montāžas metode |
DRA (adapteris uz DIN sliedes) |
Platums |
70 mm |
Augstums |
82 mm |
Dziļums |
58 mm |
Biežums |
50 Hz |
Maks. strāva (Imax) |
80 A |
Platums moduļu atstarpju skaitā |
4 |
Aizsardzības pakāpe (IP) |
IP20 |
Pulss |
1000 Imp/kWh (kvarh) |
Pole tips |
Četru vadītāju |
Nominālais spriegums (Un) NL |
230 V |
Nominālā strāva (in) |
10 A |
Iepakojuma informācija
Iepakojuma līmenis 1 |
4010312501870, 4010312501870 |
Iepakojuma līmenis 2 |
4010312501870 |
Citi tehniskie dati
Modelis |
Tiešie mērījumi |
Piemērots |
Iegāde |
Norādes veids |
Digitālais |
Kopējais pozīciju skaits (skaitītājs) |
7 |
Skaitītāja veids |
Elektroniskais |
Interfeisa veids |
Citi |
Enerģijas veids |
Efektīva jauda |
Tarifa veids |
Divu tarifu |
Tarifu kontrole |
Ārējais |
Evakuācijas mehānisms |
- |
Kalibrēts |
Yes |
Apstiprinājums |
Mērinstrumentu direktīva |
Impulsu izvade |
Optika |
Impulsa veids |
S0 |
Precizitātes klase |
B |
Mērījumu veida slodzes profils |
- |
EEC40 paraksts |
- |
Ar bloķēšanas kodu |
- |
Nominālais spriegums (Un) LL |
400 V |
Lejupielādes
Apraksts
Two-way three-phase meter. Maximum current 3x80A. Standby loss 0.5 watt per path only. Modulair device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface as standard. It measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. The active energy is added depending on the sign. Positive power in the meter means energy consumption, negative power means energy delivery. The energy measurement is balanced. If the energy consumption (P positive) is greater than the energy supply (P negative), the meter reading T arrow right is increased. If the energy supply is greater than the energy consumption, the meter reading T arrow left is increased. Energy consumption is shown with a right arrow and energy supply is shown with a left arrow above the active bar in the display. 1, 2 or 3 phase conductors with max. currents up to 80A can be connected. The inrush current is 40mA. The N terminal must always be connected. Energy consumption and energy supply values are stored in non-volatile memory and are displayed again immediately after a power failure. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 100 times per kWh. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu. First the background lighting switches on. Then the total active energy per consumption and delivery, the active energy of the resettable memory consumption and delivery as well as the instantaneous power, voltage and current values for each phase conductor can be displayed. Error message: If a phase connection is missing, the corresponding phase is shown on the display.