Register to unlock your exclusive B2B prices. Register now
CT operated three-phase energy meter, MID approval image 1

CT operated three-phase energy meter, MID approval

Noliktavas cena (bez PVN):
167,16 €
Šī cena ir spēkā līdz 2024-12-31
Cena par m: 167,16 €
EAN: 4010312501641
MPN: 28305015
Mūsu noliktava: Piegādātāja krājumi:
Vienā iepakojumā: 1 Vienā kastē: 1 Vienā paletē: N/A
Tehniskie dati
Preces stāvoklis Jauns
Ražotāja nosaukums CT operated three-phase energy meter, MID approval
Zīmols ELTAKO
Kategorijas Elektrības skaitītāji
Izcelsmes valsts CN
Harmonizētās sistēmas kods 9028 3019 00
Montāžas metode DRA (adapteris uz DIN sliedes)
Platums 70 mm
Augstums 82 mm
Dziļums 58 mm
Biežums 50 Hz
Maks. strāva (Imax) 6 A
Platums moduļu atstarpju skaitā 4
Aizsardzības pakāpe (IP) IP20
Pulss 10 Imp/kWh (kvarh)
Pole tips Četru vadītāju
Nominālais spriegums (Un) NL 230 V
Nominālā strāva (in) 5 A
Iepakojuma informācija
Iepakojuma līmenis 1 4010312501641, 4010312501641
Iepakojuma līmenis 2 4010312501641
Downloads
Citi tehniskie dati
Modelis Mērīšanas transformators
Piemērots Iegāde
Norādes veids Digitālais
Kopējais pozīciju skaits (skaitītājs) 7
Skaitītāja veids Elektroniskais
Interfeisa veids Citi
Enerģijas veids Efektīva jauda
Tarifa veids Viena tarifa
Evakuācijas mehānisms Yes
Kalibrēts Yes
Apstiprinājums Mērinstrumentu direktīva
Impulsu izvade Optika
Impulsa veids S0
Precizitātes klase B
Mērījumu veida slodzes profils -
EEC40 paraksts -
Ar bloķēšanas kodu -
Nominālais spriegums (Un) LL 400 V
Apraksts
CT operated three-phase energy meter with settable CT ratio and MID. Maximum current 3x5A. Standby loss 0.5 watt per path only. Modular device for DIN-EN 60715 TH35 rail mounting. 4 modules = 70mm wide and 58mm deep. Accuracy class B (1%). With S0 interface. This three-phase energy meter measures active energy by means of the current between input and output. The internal power consumption of 0.5 watt active power per path is neither metered nor indicated. 1, 2 or 3 phase conductors with max. currents up to 5A can be connected. The inrush current is 10mA. The N terminal must always be connected. The 7 segment LC display is also legible twice within a period of 2 weeks without power supply. Power consumption is shown by a bar flashing at a rate of 10 times per kWh. On the right next to the display are the keys MODE and SELECT. Press them to scroll through the menu according to the operation manual. First the background lighting switches on. The display then shows the total active energy, the active energy per resettable memory, and the instantaneous values of consumption, voltage and current per phase. The CT ratio can also be set. It is set to 5:5 at the factory and blocked with a bridge over the terminals which are marked with JUMPER. To adjust the CT ratio to the installed transformer remove the bridge and reset the energy meter according to the operation manual. Then block it again with the bridge. Adjustable current transformer ratios: 5:5, 50:5, 100:5, 150:5, 200:5, 250:5, 300:5, 400:5, 500:5, 600:5, 750:5, 1000:5, 1250:5 and 1500:5. Error message (false): When the phase conductor is missing or the current direction is wrong false and the corresponding phase conductor are indicated on the display. Important! Before working on the current transformers disconnect the voltage paths of the energy meters.